Wakeup calls are automatically established to the defined time. A single wakeup call is allowed at a given time. a call is first sent to the source (announcement), when the source connects, the call is sent to the object the wakeup call is configured for.

Configuration

Not/Bool
An optional Boolean object. If configured the call is sent to the given time only if the state of the boolean object is true. With the Not checkmark set the call is sent if the state of the boolean object is false.
Hour
The hour of the day, to which the wakeup call is executed. This referes to the local time of the PBX.
Min
The minute to which the wakeup call is executed. If no hour is configured, the wakeup call is executed each hour.
Sec
The second to which the wakeup call is executed. If no hour and no minute is configured, the wakeup call is executed each minute. The clock resolution for wakeup calls is 10s, so the wakeup call is executed within a 10s interval after the configured time.
Source Name
Name which is called for the announcement source (if no Name or Number' is configured the default MOH is used as source)
Number
Number which is called for the announcement source (if no Name or Number is configured the default MOH is used as source)
Retry
Number of Retries, if Source or Destination do not connect
Multiple
If this checkmark is set, the wakeup call is executed periodically until it is removed. If not set, the wakeup call is removed after execution.
Timeout
Timeout to limit the time the wakeup call is alerting at the user. After the timeout the call is disconnected.
Fallback
Number to be called when the wakeup failed. The wakeup failed if the call was never alerting at the user after the configured retries, or if the Timeout expired, so the call was alerting the configured time, but was not answered.