Limitations

There are various global restrictions in the config size:

  • the total size of "config change" commands must not exceed 29kB
  • the total line length must not exceed 20kB (for v11r2 and earlier versions the limit is 8kB)
  • the number of whitespace separated strings (words) on a config line must not exceed 1024

There are some special restrictions in the config size:

  • No more than 32 alias entries are allowed on one Gatekeeper/Registrar interface.
  • No more than 6 Hardware IDs on a PBX Object are possible.

So if there is a problem, you can try to use shorter aliases, leave out redundant informations. Nevertheless, it is ugly.

Online Calculator of bytes on String - https://mothereff.in/byte-counter

Weak Scenarios and alternative Solutions

Many number mappings in the routing engine

Use PBX Features instead: