Howto:Power Consumption: Difference between revisions
Line 218: | Line 218: | ||
=== PoE Injector Capacity === | === PoE Injector Capacity === | ||
All PoE injector offered by innovaphone (order code 03-00010-228 and 03-00010-231) fullfill the power demand PoE capable innovaphone devices need (generally 15W at PSE side). This is good for any device up to PoE class 3. | |||
==Supply via Power Supply Unit (PSU)== | ==Supply via Power Supply Unit (PSU)== |
Revision as of 10:25, 20 December 2013
Supply via Power over Ethernet (PoE)
Power level
The power consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
Class | Usage | Power level PSE [W] | Power level PD [W] |
0 | default | 15,4 | 0,44 - 12,95 |
1 | optional | 4 | 0,44 - 3,84 |
2 | optional | 7 | 3,84 - 6,49 |
3 | optional | 15,4 | 6,49 - 12,95 |
4 | reserved | 15,4 | 0,44 - 12,95 |
Power level of innovaphone devices
Gateways:
Device | PoE-Class | average total input power [mW]* | max total input power [mW]* |
IP22 | 3 | 3000 | 4600 |
IP24 | 3 | 3600 | 6800 |
IP28 | 3 | 4000 | 12900 |
IP38 | 1 | 2800 | 3800 |
IP302 | 3 | 3000 | 4800 |
IP305 | 2 | 2900 | 3000 |
IP800 up to HW201 | 0 | ||
IP800 ex HW300 | 3 | 4700 | 10500 |
IP2000 | 3 | 5900 | 6500 |
IP6000 | 3 | 9800 | 10000 |
IP1200 | 0 | 5000 | 8000 |
IP1202 | 2 | 4000 | 5000 |
IP0010 | 3 | 8000 | 12500 |
IP3010 | 3 | 8000 | 12500 |
IP6010 | 3 | 8000 | 12500 |
IP1060 | 3 | 8000 | 12500 |
IP810 | 3 | 8000 | 12500 |
Phones:
Device | PoE-Class | average total input power [mW]* | max total input power [mW]* | manufacturing check [mW]** |
IP110 | 1 | 2500 | 2700 | 3500 |
IP200A | 1 | 2900 | 3200 | 3500 |
IP230 | 2 | 2600 | 2900 | 3500 |
IP240 | 2 | 3100 | 3800 | 4000 |
IP150 | 1 | 2800 | 3000 | 3500 |
IP240-1000 | 2 | 4900 | 5900 | 6500 |
IP230-x | extension module | 1000 | 1000 | |
IP241 | HW < 402 = 3
HW >= 402 = 2 |
< 3500 | ||
IP222 | 2 | 4800*** | ||
IP232 | 2 | 4900*** |
*These values were averaged results from simulating normal and maximum use. To have an official max total input power value please orientate on the upper limit of the associated PoE class.
**All devices leaving the manufacturing process are checked whether the cunsumption is under this value.
***LAN and PC interface connected with 1Gbit/s. 4xUSB connected (only IP2x2).
Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X
5.9W +3*1W= 8.9W
Estimated worst case power consumption for operation of a 240 with 3 IP230-X
3.8W +3*1W= 6.8W
PoE Injector Capacity
All PoE injector offered by innovaphone (order code 03-00010-228 and 03-00010-231) fullfill the power demand PoE capable innovaphone devices need (generally 15W at PSE side). This is good for any device up to PoE class 3.
Supply via Power Supply Unit (PSU)
Most of the innovaphone devices can be supplied by an external PSU (exception: IP800; IP2000; IP6000 with build in power supply). All testreadings were determined by measuring the power consumption of the PSU. They are no official numbers. The following tables are showing different phone modes. All values in mW.
12V PSU for phones
Without using switch functionality (only LAN is connected 100Mbit/s):
Device | Standby | On-Hook | Active (handsfree with max loudness) | Ringing |
IP110 | 2900 | 3000 | 3400 | 3000 |
IP200A | 3400 | 3500 | 3900 | 3500 |
IP230 | 3000 | 3300 | 3500 | 3300 |
IP240 | 3400 | 3700 | 3800 | 3700 |
IP240-1000 | 5200 | 5500 | 5700 | 5500 |
IP241 | < 3500 | |||
IP222 | 2500 | |||
IP232 | 2600 |
Using switch functionality (PC + LAN is connected 100Mbit/s):
Device | Standby | On-Hook | Active (handsfree with max loudness) | Ringing |
IP110 | 3300 | 3400 | 3700 | 3400 |
IP200A | 3900 | 3900 | 4400 | 3900 |
IP230 | 3400 | 3600 | 3800 | 3600 |
IP240 | 3800 | 4100 | 4200 | 4100 |
IP240-1000 | 7400 | 7700 | 7900 | 7700 |
IP241 | 4500*** | |||
IP222 | 4200*** | |||
IP232 | 4300*** |
Because of the increased power consumption during usage with three IP230-X a more efficient PSU is needed. Please use the 40V Gateway PSU from innovaphone.