Problem Details

In contrast to the innovaphone devices, that allows you to specify the IP v4 TOS header field value used for voice and signalling IP packets, the MS Windows based applications like SoftwarePhone and myPBX do not have any possibility to set ToS Values on the RTP packets due restriction of the Microsoft Windows operating system.

Instead to set the ToS Value in the Application the Policy-based Quality of Service (QoS) provided by the MS Windows operating system can be used to mark the IP packets.

Usually the configuration of the Policy-based Quality of Service is done by defining a Group Policy Object (GPO) in the Group Policy Management Console (GPMC). This could be done for a single computer or distributed to a number of computers via the domain controller.

In the Windows 8 and Server 2012 it is possible to use PowerShell to configure the values with the Set-NetQosPolicy Cmdlet.


Microsoft Windows QoS Policy Mappings for innovaphone Applications
Policy Name Application Path Protocol Source Port Destination Port Source IP / Mask Destination IP / Mask DSCP Value Throttling Rate
innovaphone myPBX Video RTP %programfiles(x86)%\\innovaphone\\myPBX\\myPBX.exe UDP 50000:50100 * * * 34 -1
innovaphone myPBX Signalling HTTP %programfiles(x86)%\\innovaphone\\myPBX\\myPBX.exe TCP * 80 * * 26 -1
innovaphone myPBX Signalling HTTPS %programfiles(x86)%\\innovaphone\\myPBX\\myPBX.exe TCP * 443 * * 26 -1
innovaphone SoftwarePhone Audio RTP %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe UDP 16384:32767 * * * 46 -1
innovaphone SoftwarePhone Signalling RAS %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe UDP * 1718:1719 * * 26 -1
innovaphone SoftwarePhone Signalling H225 %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe TCP * 2048:59999 * * 26 -1
innovaphone SoftwarePhone Signalling H323/TCP %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe TCP * 1720 * * 26 -1
innovaphone SoftwarePhone Signalling H323/TLS %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe TCP * 1300 * * 26 -1
innovaphone SoftwarePhone Signalling SIP %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe TCP/UDP * 5060 * * 26 -1
innovaphone SoftwarePhone Signalling SIPS %programfiles(x86)%\\innovaphone\\SoftwarePhone\\softwarephone.exe TCP * 5061 * * 26 -1


The DSCP Values in the above example are default DSCP values used by innovaphone devices, according to the Wiki article Howto:Calculate Values for Type of Service (ToS) from DiffServ or DSCP Values. You may change this values to meet requirements on your traffic prioritisation and routing equipment.

The GPO is stored on the local computer in the registry. The following registry export file could be used to setup QoS Values on the local computer:

Windows Registry Editor Version 5.00

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS]

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone myPBX Signalling HTTP]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\myPBX\\\\myPBX.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="80"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone myPBX Signalling HTTPS]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\myPBX\\\\myPBX.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="443"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone myPBX Video RTP]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\innovaphone\\myPBX\\myPBX.exe"
"Protocol"="UDP"
"Local Port"="50000:50100"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="*"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="34"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Audio RTP]
"Version"="1.0"
"Application Name"="C:\\Program Files (x86)\\innovaphone\\SoftwarePhone\\softwarephone.exe"
"Protocol"="UDP"
"Local Port"="16384:32767"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="*"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="46"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling H225]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="2048:59999"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling H323/TCP]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="1720"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling H323/TLS]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="1300"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling RAS]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="UDP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="1718:1719"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling SIP]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="*"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="5060"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"

[HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows\QoS\innovaphone SoftwarePhone Signalling SIPS]
"Version"="1.0"
"Application Name"="%programfiles(x86)%\\\\innovaphone\\\\SoftwarePhone\\\\softwarephone.exe"
"Protocol"="TCP"
"Local Port"="*"
"Local IP"="*"
"Local IP Prefix Length"="*"
"Remote Port"="5061"
"Remote IP"="*"
"Remote IP Prefix Length"="*"
"DSCP Value"="26"
"Throttle Rate"="-1"