Howto:Volume levels on an IP50 or IP52, IP54: Difference between revisions

From innovaphone wiki
Jump to navigation Jump to search
No edit summary
(gpa - Kirk information ("Notice") über max. ringtone adjustment hinzugefügt)
Line 58: Line 58:
Turn the Handset off and on to re-read the new settings
Turn the Handset off and on to re-read the new settings


  '''Notice:'''
  There are some different depending of the handsets maximum ringtone volume adjustment:
  Within the Kirk service tool it is only possible to adjust the max. ringtone volume for IP50 Handsets.
 
  IP50: Raising the maximum ringtone volume is possible.
  IP52/54: It is not possible to adjust the max. ringtone volume on IP52 and IP54 Handsets!
    The reason is that the ringing signal is send out in the same area where you have the loadspaker.
    If for any reason someone helds the handsets to her/his ear, there is a limitation how high this signal can be.
   
==Related Articels==
==Related Articels==



Revision as of 11:17, 16 October 2008

Volume Levels for Mic and Speaker Gain can be set on the handsets too.

Applies To

This information applies to

  • IP 50
  • IP 52
  • IP 54


More Information

The volume on the handset is too low, although the speaker level is set to maximum via the volume keys.

System Requirements

Windows PC with serial interface

· Kirk Service Tool

. for download see related articel

· Programming cable

· IP50 programming cradle (DECT Charger with 3 Pins)

· IP52/54 programming cradle (DECT Charger with 3 Pins)

· Y-Connector

· Power Supply (for IP50 or IP52/54 DECT Charger)


Installation

Install the Kirk Service Tool following the instruction on the screen.

Connect the Y-Connector in the with on side to the docking station, on the other side connect the power supply and the programming cable to the connector.

Put the programming cable with the serial connector into the PC.

Plug in the Power Supply and insert a Handset to the cradle.


Configuration

In the Kirk Tool setup the following points:

· Communication Tab

. your COM Port

. PP1-PP4 … for IP50 Handsets

. PP5/40XX for IP52/54 Handsets

Put the Handset into the cradle and hit “set comport” in the Communications Tab. A Message like “PP connected” should appear in the bottom line of the Servic Tool Window.

Now go to the Gain Control Tabs, “Gain Control” for IP50 and “Gain Control 40XX” for IP52/IP54 Handsets. First read the old values from the Handset by pressing on “Read gain value” and adjust the values to your needs.

After that write them back to the Handset with pressing the “Write gain values”.

Turn the Handset off and on to re-read the new settings

 Notice:
 There are some different depending of the handsets maximum ringtone volume adjustment:
 Within the Kirk service tool it is only possible to adjust the max. ringtone volume for IP50 Handsets.
 
 IP50: Raising the maximum ringtone volume is possible.
 IP52/54: It is not possible to adjust the max. ringtone volume on IP52 and IP54 Handsets!
   The reason is that the ringing signal is send out in the same area where you have the loadspaker.
   If for any reason someone helds the handsets to her/his ear, there is a limitation how high this signal can be.
   

Related Articels

service tool