SIP Interworking with Siemens HIPath 4000

3rd party input
this is 3rd party content not provided by innovaphone, see history for authors.

Summary

SIP trunking between innovaphone PBX and Siemens HIPath 4000 PBX. It is recommended to use V5 on Siemens PBX, older Versions are not stable and also not fully SIP featured. Tested by our german partner Telesys.

Certification Status

Referralprod.PNGThis product is listed due to a customer testimonial. No tests have been conducted by innovaphone.

Testing of this product has been finalized March 15th, 2010.

Version

  • Siemens HIpath 4000, Interface card HG 3500
  • Version 5.0
  • innovaphone Firmware: v8 HF1


Configuration

SIP trunking without registration

On the Siemens PBX SIP native must be configured, on innovaphone side configure a Gateway interface without registration , protocol SIP/UDP. For configuration details see below.

Test Results

Basic Call

Tested feature Result
call using g711a Yes
call using g711u Yes
call using g729 Yes
Overlapped sending Yes
Early media channel Not tested
Device shows called id number Yes
Device shows called id name One Way - works only from innovaphone to Siemens, call in the other way name shows only up at innovaphone phone
Device shows called id display info One Way - works only from innovaphone to Siemens, call in the other way name shows only up at innovaphone phone
Fax using T.38 Yes
CGPN can be supressed Yes
Reverse Media Negotiaton Not tested
Device shows CDPN/CGPN on incoming call Yes
Device shows CDPN/CGPN on outgoing call Yes
Device shows connected number No
Device shows diverting number No
Device supports distinctive ringing Yes
Device supports asymetric codec negotiation Yes
Device supports codec renegotiation during a conversation No *
Device shows correct display message in case of busy CDPN Yes
Device shows correct display message in case of not existing CDPN Yes
Device shows correct display message in case that the call is declined Yes
Long Time Call (>30 min) works? Not tested
Voice Quality OK? Yes
  • it is recommended that you configure Media relay and a fixed codec on the innovaphone gateway, as the Siemens PBX does not support codec renegotiation.

DTMF

Tested feature Result
DTMF tones sent correctly Yes
DTMF tones received correctly Yes


Hold/Retrieve

Tested feature Result
Device handles incoming hold correctly Yes
Device can put a call on hold using correctly(inactive or sendonly) Yes

Transfer with consultation

Tested feature Voice Ok? MoH Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes Yes
inno1 calls inno2. inno1 transfers to siemens. Yes Yes
inno1 calls siemens. inno1 transfers to inno2. Yes Yes
inno1 calls siemens. siemens transfers to inno2. Yes Yes
siemens calls inno1. inno1 transfers to inno2. Yes Yes
siemens calls inno1. siemens transfers to inno2. Yes Yes

Transfer with consultation (alerting only)

Tested feature Voice Ok? MoH Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes Yes
inno1 calls inno2. inno1 transfers to siemens. Yes Yes
inno1 calls siemens. inno1 transfers to inno2. Yes Yes
inno1 calls siemens. siemens transfers to inno2. Yes Yes
siemens calls inno1. inno1 transfers to inno2. Yes Yes
siemens calls inno1. siemens transfers to inno2. Yes Yes

Blind Transfer

Tested feature Voice Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes
inno1 calls inno2. inno1 transfers to siemens. Yes
inno1 calls siemens. inno1 transfers to inno2. Yes
inno1 calls siemens. siemens transfers to inno2. Yes
siemens calls inno1. inno1 transfers to inno2. Yes
siemens calls inno1. siemens transfers to inno2. Yes

Blind Transfer (alerting only)

Tested feature Voice Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes
inno1 calls siemens. siemens transfers to inno2. Yes
siemens calls inno1. inno1 transfers to inno2. Yes

Broadcast Group & Waiting Queue

Tested feature Result
siemensmakes call to a Broadcast Group. inno1 picks up. Yes
inno1 makes call to a Broadcast Group. siemens picks up. No
siemens makes call to a Waiting Queue. inno1 picks up before announcement is played. Yes
siemens makes call to a Waiting Queue. inno1 picks up after announcement is played. Yes
inno1 makes call to a Waiting Queue. siemens picks up. No

Configuration

innovaphone configuration

For calls to the Siemens configure a Gateway Interface without registration, as Proxy put the Ip address of the Siemens HG3500 module.


Howto-SIP Interworking Interoperability HiPath 4000 Hipath3.png


If you deal with different codecs (different innovaphone phones with different preferred codec settings and/or different MOH or WQ codec files), it is recommended that you set your codec settings on the Gateway interface to the Siemens HIPath to exclusive. Also use Media relay as the Siemens can get in troubles having invites from different Ip addresses.


In the routes enable the Interworking flag in both ways.

SIP Interworking Interoperability HiPath 4000 Hipath4.png

The innovaphone can send digits with overlap to the Siemens HIPath, so no en-block enabling is necessary.

3rd party product configuration

Here it shows how to configure the Siemens HIPath in detail (in German language)

HIPath configuration

Known Problems

  • On Siemens side en-block dialing must be enabled, as the Siemens can only send numbers via Sip in en-block dial.
  • CCBS/CCNR is not possible.
  • Calls from Siemens to innovaphone, the connected Name will not be shown up on the Siemens Endpoint.
  • Connected Name does not show up on Siemens phones when calling from Siemens to innovaphone

Having older Versions on HiPath

HiPath 4000 V1 – connecting only possible via BRI/PRI
HiPath 4000 V2 – connecting only possible via BRI/PRI
HiPath 4000 V3 – connecting only possible via BRI/PRI (H.323 only basic call- not recommended)
HiPath 4000 V4 – connecting only possible via H.323/BRI/PRI 
HiPath 4000 V5 – connecting only possible via SIP/H.323/BRI/PRI

Related Articles

Howto:HiPath4000 Interconnection

Howto:How to interwork with a Hicom 150/HiPath 3000

Howto:How_to_configure_Cornet-NQ_trunking_on_a_Hicom300/HiPath_4000