Reference9:3pty conference on DECT phones: Difference between revisions
No edit summary |
|||
Line 18: | Line 18: | ||
* PBX: The innovaphone CONF interface is registered to a PBX Trunk Line object (or a Gateway object with the ''Prefix'' check-mark ticked). The Trunk Line must have a number and be called by the gatekeeper the DECT users are registered. | * PBX: The innovaphone CONF interface is registered to a PBX Trunk Line object (or a Gateway object with the ''Prefix'' check-mark ticked). The Trunk Line must have a number and be called by the gatekeeper the DECT users are registered. | ||
* IP-DECT device: The ''Conferencing Unit Number'' of the DECT Master is to be set to the Trunk Line number appended by ''*1#''. | * IP-DECT device: The ''Conferencing Unit Number'' of the DECT Master is to be set to the Trunk Line number appended by ''*1#'' (If Trunk Line is ''8'', set ''Conferencing Unit Number'' to ''8*1#''). | ||
=== Usage === | === Usage === |
Revision as of 18:11, 28 October 2019
This article explains how to configure and use 3pty conference calls on DECT phones.
Applies To
This information applies to
- all innovaphone DECT devices (IP1200 and IP1202) from V9HF11.
More Information
The innovaphone IP-DECT devices are able to use the innovaphone conference hardware (CONF interface) to establish a 3pty conference call with firmware V9 hotfix 11 or later. If the 3pty conference is started by the user, first the IP-DECT device starts a call to the configured conferencing unit number. If this call connects, the connected number is used to connect the other call parties to the conference call.
Requirements
- innovaphone IP-DECT device with firmware V9 hotfix 11 or later
- innovaphone device with CONF interface with support of connected number (V9 and later)
Configuration
- PBX: The innovaphone CONF interface is registered to a PBX Trunk Line object (or a Gateway object with the Prefix check-mark ticked). The Trunk Line must have a number and be called by the gatekeeper the DECT users are registered.
- IP-DECT device: The Conferencing Unit Number of the DECT Master is to be set to the Trunk Line number appended by *1# (If Trunk Line is 8, set Conferencing Unit Number to 8*1#).
Usage
To start a conference by a DECT phone use the R-key feature R+3 during a call. You must have at least one inactive call. To stop the conference again use also R+3. R+2 stops the conference and toggles to the last inactive party, or to a waiting call, if present.