Howto:Connect to MX-ONE via H.323
Applies To
This information applies to
All innovaphone gateways with V6 and V7.
Tested with IP800.
Problem Details
It is not possible to establish a H.323 connection without specifying the name of the Innovaphone unit in the MX-ONE, it is however not nessesery to specify a name of the MX-ONE in the Innovaphone, just not good practice.
System Requirements
IP-connection to MX-One
Configuration
This is an example using IP800 version 7:
MX-ONE connection setup:
ROCAI:ROU=10,SIG=011111100091,SERV=21100000070,SEL=0110000000000010,TRAF=03151515,TRM=6,BCAP=001100;
RODAI:ROU=10,TYPE=TL65,VARC=00000111,VARI=00000011,VARO=00000000;
RIANI:ROU=10,IP=10.102.77.25,LROUID="HMM",RROUID="ASCOM",CODECS=b-0;
RODDI:DEST=51,ROU=10,SRT=1,ADC=062610000000005000600000000;
ROEQI:ROU=10,TRU=1-10,IP=10.102.77.25;
IP800 connection setup:
Known Problems
Suppress HLC must be turned on. If not, I could not make my IP110's work. They could not make calls to the MX-ONE. However, the ASCOM DECT phones and analog phones (IP24) was OK without the Suppress HLC turned on!!!!
Calls from MX-ONE to the Innovaphone system worked regardless of the Suppress HLC was on or off
Only basic features are tested.