===System Requirements===
===System Requirements===
You can use either IPVA's or our Hardware devices to setup the complete scenario.
For the Funnel-PBX you will probably use an IPVA because you don't need any Fysical Hardware interfaces like PRI or BRI.
In the Sub-locations it depends on your needs, the amount of users and the Fysycal interfaces  for integrating with a legacy PBX.
===Licenses===
What kind of licenses do you need and how many ?
'''Funnel-PBX.'''
In the Funnel_PBX you need only Port-licenses. The amount depends on your needs. You need at least 1 Port lic. for the internal registration of the Central-Trunk to your SIP Provider. Further you need 1 Port lic. for every sub-location that registers on the Gateway Object of that Location.
'''Location-PBX.'''
How many and what kind of licenses you need in the Location-PBX, is depending on the scenario and the customer needs.
The posible scenarios are:
* you have standalone PBX on the locations, you need the licenses in your Location-PBX and you need the appropiate Interface licenses (BRI,PRI,TEL)
* you have a Master-Slave (e164) scenario, you need all the Port licenses in your Master PBX and the appropiate Interface licenses (BRI,PRI,TEL) in your Location-PBX
You need at least 1 Port lic. for the Trunk-Line Object of the Location-PBX and 1 Port lic. for your Trunk to the Legacy-PBX (if applicable).
Depending on the customer needs you will have to add the Port lic per User Object and if desired also the UC-licenses per User Object.
'''For example:'''
You have 65 Sub-locations (with a Legacy-PBX) and 1 Headquarter (with a Legacy-PBX).
'''IPVA Funnel-PBX:'''
1 Port lic.  Central-Trunk to SIP provider
1 Port lic. per location for (Registered Gateway Object)
N locations = 66 (HQ+65 sub-locations)
Total amount of Port lic in hte Funnel-PBX = 67 Port lic.
'''IPVA Master PBX and Slave locations:'''
Slave locations = N locations
1 Port lic. per location Trunk-line (0)
1 Port lic. per location to Legacy-PBX(SIP or ISDN)
N Locations = 66 (HQ + 65 sub-locations)
Total amount of Port lic. in the Master-PBX = 66 Port lic.
'''Extra Licenses recommended:'''
x Port lic. for IP-Phones or analog ports on location(s)
x UC licenses per user
The total amount of hardware licenses is depending on the Location-PBX, used device and used Interface(s). In a IP411 and IP311 the hardware licenses are already included, for a IP811 and IP3011 you need to add the approiate amount of hardware licenses and relay-channel licenses.


===Installation===
===Installation===

Revision as of 14:04, 21 November 2017

Applies To

This information applies to

V12r2 sr6 Build 12.5236 and later.


More Information

In this scenario every customer site is an innovaphone Gateway/PBX providing PBX functionality or Gateway functionality with ISDN PRI BRI or SIP Trunk to a legacy PBX on a location. In stead of having a ISDN or SIP Trunk to the PSTN network on every location, there will be a Central big sip trunk on one location that provides the PSTN access for all other locations. The call routing is made by innovaphone PBX containing e164 node tree with appropriate placed Gateways for each customer location.

Overview

The following diagram shows a simple scenario of a Funnel PBX with N locations providing a central big sip trunk for all sub-locations. The sub-locations provding PBX functionality as wel the gateway-functionality to a legacy PBX for migrations.

Simple e164-scenario Funnel PBX.png


Configuration of the Funnel PBX

Start with configurating your Funnel PBX with the following Objects:

  • Node Objects with the Country Code, in this example the Node Objects for NL (Netherlands) with country code 31.
  • Node Objects with the location and prefix of the location, in this example the Node Objects for the locations Roermond (RM) and Maastricht (MT).
  • Gateway Objects with the prefix for the PBX-locations, so that the PBX/Gateway on that location can register against this opbject via SIP.
  • Number Map Objects for the locations, in case you don't have a closed DID range but one or more MSN numbers, you can create these as a Number Map Object and route the call to the desired number or object within a location.
  • Trunk Line Object in the Funnel-PBX, the central trunk line object that register at the big sip trunk and an internal registration to the Funnel-PBX.

Although that in some examples the password field is left blank, you should consider security and cofigure safe passwords for all objects !


Funnel-PBX Objects Create the Funnel PBX Objects like in this example NL with country code 31

Funnel-PBX Objects.png

Node Object General

Create the Node Object with the country code

Node Object General.png and Node Object Node Node Object Node.png

Node Object General

Create the Node Object for the locations like in this example MT with area code 43

Node Object General MT.png and Node Object Node Node Object Node MT.png

Gateway Object General

Create the Gateway Object for the PBX/Gateway in the location. In this example with PBX prefix 7630.

Gateway Object General.png Gateway Object Gateway Gateway Object Gateway.png

Repeat these steps for all the locations in your scenario.

Trunk Line Object

Create a Trunk Line Object Central-Trunk. The number field in the Trunk Line Object is left blank by purpose. The reason is to avoid this number to be displayed in your telephone set after the connection has been established (Connected Number).

Trunk Line Object General.png

Choose some reasonable destinations for Loopback, Incomplete, Invalid, Busy, Rejected and No Answer. For example the Operators destination number in the HeadOffice.

Trunk Line Object Trunk.png

Configuration of a location PBX-Gateway

The PBX in the locations can be a Single Master PBX, a slave PBX or slave PBX that is part of an e164 Large PBX configuration. The type of PBX doesn't matter for the registration to the Funnel-PBX. The registration to the Funnel PBX is done via a SIP trunk registration to the Gateway Object in the Funnel-PBX.

The Configuration of the SIP trunk is shown in the picture.

MT-Location SIP Trunk Configuration.PNG


If Configured OK the registration is visable on both sides, the Location PBX and the Funnel-PBX.

MT-Location Gateway SIP Trunk registration.PNG

Funnel PBX Registrations.PNG

To route the incomming calls correctly to the Called Party Number CDPN and present the correct Calling Party Number CGPN with outgoing calls, we have to create some changes in the Routes of the Local PBX.


MT-Location Routes Configuration.PNG

In the Maastricht location we use as single MSN number 31 43 7777 579. Because this number is not part of the DID range 7630 xxx, we have to create a single number map to the desired destination, preferable a number in the original DID range.


Rest is still under construction


In this example the PBX in the location Maastricht is also part of an e164 Large PBX configuration. So don't get confused by the Objects in this PBX that has no relation with the Funnel-PBX.

System Requirements

You can use either IPVA's or our Hardware devices to setup the complete scenario. For the Funnel-PBX you will probably use an IPVA because you don't need any Fysical Hardware interfaces like PRI or BRI. In the Sub-locations it depends on your needs, the amount of users and the Fysycal interfaces for integrating with a legacy PBX.


Licenses

What kind of licenses do you need and how many ?

Funnel-PBX.

In the Funnel_PBX you need only Port-licenses. The amount depends on your needs. You need at least 1 Port lic. for the internal registration of the Central-Trunk to your SIP Provider. Further you need 1 Port lic. for every sub-location that registers on the Gateway Object of that Location.

Location-PBX.

How many and what kind of licenses you need in the Location-PBX, is depending on the scenario and the customer needs.

The posible scenarios are:

  • you have standalone PBX on the locations, you need the licenses in your Location-PBX and you need the appropiate Interface licenses (BRI,PRI,TEL)
  • you have a Master-Slave (e164) scenario, you need all the Port licenses in your Master PBX and the appropiate Interface licenses (BRI,PRI,TEL) in your Location-PBX


You need at least 1 Port lic. for the Trunk-Line Object of the Location-PBX and 1 Port lic. for your Trunk to the Legacy-PBX (if applicable).

Depending on the customer needs you will have to add the Port lic per User Object and if desired also the UC-licenses per User Object.


For example:

You have 65 Sub-locations (with a Legacy-PBX) and 1 Headquarter (with a Legacy-PBX).


IPVA Funnel-PBX:

1 Port lic. Central-Trunk to SIP provider

1 Port lic. per location for (Registered Gateway Object)

N locations = 66 (HQ+65 sub-locations)

Total amount of Port lic in hte Funnel-PBX = 67 Port lic.


IPVA Master PBX and Slave locations:

Slave locations = N locations

1 Port lic. per location Trunk-line (0)

1 Port lic. per location to Legacy-PBX(SIP or ISDN)

N Locations = 66 (HQ + 65 sub-locations)

Total amount of Port lic. in the Master-PBX = 66 Port lic.


Extra Licenses recommended:

x Port lic. for IP-Phones or analog ports on location(s)

x UC licenses per user


The total amount of hardware licenses is depending on the Location-PBX, used device and used Interface(s). In a IP411 and IP311 the hardware licenses are already included, for a IP811 and IP3011 you need to add the approiate amount of hardware licenses and relay-channel licenses.

Installation

Problem Details