Howto:Bypass the setup wizard/install

From innovaphone wiki
Revision as of 10:27, 28 January 2014 by Tle (talk | contribs) (→‎Resolution)
Jump to navigation Jump to search

Applies To

This information applies to

  • all innovaphone devices,

Firmware V6 SR2 and later.


More Information

Problem Details

From Version 6, Service Release 2 on, innovaphone devices will run a configuration wizard when accessed reset to factory settings. While this is a great to speed up deployment of innovaphone boxes, it may be required to bypass the wizard in certain situations.

Resolution

To bypass the wizard, access http://x.x.x.x/admin.htm (or http://x.x.x.x/administrator.htm for V7 and later) instead of http://x.x.x.x to access the standard configuration interface.

Nb: from version 9 firmware on, the URL to bypass the wizard is http://x.x.x.x/admin.xml?xsl=admin.xsl.

To get rid of the wizard permanently, you may remove the /home SETUP/wizard.xml parameter from the config change HTTP0 line.

You can do that by doing the commands:

http://x.x.x.x/!config change HTTP0
http://x.x.x.x/!config write
http://x.x.x.x/!config activate
http://x.x.x.x/!ireset