Applies To
This information applies to
All innovaphone devices, Version 7 and later
More Information
Problem Details
Sometimes it is desirable to set a device to factory defaults using the web interface. Here is how.
Resolution
Use the following command sequence (using e.g. http://x.x.x.x/!cmd
):
config clear config write vars del mod cmd FLASHMAN0 reset data erase ireset
Note: as opposed to CF-Card/SSD drives, the Flash Disk (/DRIVE/FLASH
) is erased durign a factory reset. To mimic this behaviour as close as possible, you can additionally use
mod cmd FLASH remove /block mod cmd FLASH format /block
for devices with a Flash Disk. This will (re-) format the drive.
Known Problems
- The procedure might change with releases.
- Factory settings do also apply to the IP/DHCP configuration. The device may thus be unreachable after.
- This doesn't apply to innovaphone Softwarephone.
- The procedure removes also the important option /cipher in the DECT base station (IP1202, not IP1200) which is needed. This is fixed in V10sr15 and V9hotfix41 and later versions, or call this command to fix it after the clear command:
config add DECT /cipher config write
- The update url is missing after this factory reset, so
http://config.innovaphone.com/init
needs to be added to the update url for provisioning to work.