Howto:HiMed - Testreport
Jump to navigation
Jump to search
Summary
Testing of this product has been finalized 28th of February, 2019.
Version
Firmware Version:
10.51 Pro20
innovaphone Firmware:
12R2 SR21
Test Setup
Device Setup
Test Results
Basic Call
Tested feature | Result |
---|---|
DHCP is default | Yes |
DHCP yields correct default gateway | Yes |
Device registers by extension | Yes |
Device registers with password | Yes |
Device registers multiple identities | Yes |
Device supports STUN protocol | No |
Device usable in hosting scenarios? | Yes |
Device supports SIP over TCP | No |
Device supports SRTP | No |
Device supports SIPS (SIP over TLS) | No |
Device supports VAD (Voice activity detection) | No |
Tested feature | Result |
---|---|
call using g711a | Yes |
call using g711u | No |
call using g729 | No |
call using g722 | Yes |
Overlapped sending | No |
CGPN can be suppressed | No |
Device shows connected number | Yes |
Device shows diverting number | No |
Device shows correct display message in case that the call is declined | Yes |
Long Time Call (>30 min) works? | Yes |
Voice Quality OK? | Yes |
DTMF
Tested feature | Result |
---|---|
DTMF tones sent correctly | Yes |
DTMF tones received correctly | Yes |
RFC 2833 | Yes |
SIP Info | No |
inband-DTMF | No |