Howto:Looping a innovaphone PBX behind a Nortel Meridian option 11c: Difference between revisions

From innovaphone wiki
Jump to navigation Jump to search
m (This article will describe a loop in scenario from a Innovaphone PBX behind a Nortel Meridian option 11 C. This article discripe the Seetings from the Nortel PBX for a QSIG conection.)
 
 
(One intermediate revision by one other user not shown)
Line 10: Line 10:


===Problem Details===
===Problem Details===
If we loop a Innovaphone PBX behind a Nortel PBX, we have often a Problem with no way audio channel. The Problem is that the Nortel PBX used the Timeslot 16 with the Channel 31. The Timeslot 16 is for the Signaling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signaling
If we loop a Innovaphone PBX behind a Nortel PBX, we have often a problem with no way audio channel. The problem is that the Nortel PBX used the timeslot 16 with the Channel 31. The Timeslot 16 is for the signalling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signalling.




Line 16: Line 16:


===Configuration of the Innovaphone Pri Interface===
===Configuration of the Innovaphone Pri Interface===
Configuration / Pri / Protocol / QSIG ECMA1
Configuration / Pri / Interop :


all Options diabled
*Configuration / Pri / Protocol / QSIG ECMA1
and CR Length ,CHI Type default
*Configuration / Pri / Interop :
**all Options disabled and CR Length, CHI Type default




===Configuration of the Nortel Pri Interface===
===Configuration of the Nortel Pri Interface===
Please find below the Nortel D Channel configuration used for Innovaphone VoIP integration.
Please find below the Nortel D Channel configuration used for Innovaphone VoIP integration.
Settings from the Nortel Meridian option 11c.
PT2000,
REQ prt,
TYPE adan dch 12,
ADAN DCH 12,
CTYP MSDL,
CARD 02,
PORT 1,
DES QSIG,
USR PRI,
DCHL 2,
OTBF 32,
PARM RS422 DTE,
DRAT 64KC,
CLOK EXT,
IFC ISIG,
ISDN_MCNT 300,
CLID OPT0,
CO_TYPE STD,
SIDE USR,
CNEG 1,
RLS ID **,
QCHID NO ---------  '''By default this will be YES.Changed this to NO to make Timeslot values 17 to 31 of the PR12 loop associated with channel number 16 to 30 of the Channel Identification IE''',


RCAP NCT COLP,
MBGA NO,
OVLR NO,
OVLS NO,
T310 120,
T200 3,
T203 10,
N200 3,
N201 260,
K 7,


Settings of the Nortel Meridian option 11c:


*PT2000,
*REQ prt,
*TYPE adan dch 12,
*ADAN DCH 12,
*CTYP MSDL,
*CARD 02,
*PORT 1,
*DES QSIG,
*USR PRI,
*DCHL 2,
*OTBF 32,
*PARM RS422 DTE,
*DRAT 64KC,
*CLOK EXT,
*IFC ISIG,
*ISDN_MCNT 300,
*CLID OPT0,
*CO_TYPE STD,
*SIDE USR,
*CNEG 1,
*RLS ID **,
*QCHID NO, -------  '''QCHID is YES by default. Change it to NO to make timeslot values 17 to 31 of the PR12 loop associated with channel numbers 16 to 30 of the Channel Identification IE'''
*RCAP NCT COLP,
*MBGA NO,
*OVLR NO,
*OVLS NO,
*T310 120,
*T200 3,
*T203 10,
*N200 3,
*N201 260,
*K 7,


Related Articles : Howto:Looping in a innovaphone Gateway
== Related Articles ==
[[Howto:Looping in a innovaphone Gateway]]


[[Category:Howto|{{PAGENAME}}]]
[[Category:Howto|{{PAGENAME}}]]

Latest revision as of 11:27, 9 April 2009

Applies To

This information applies to

  • IP 6000,IP3000 V6/ V7
  • IP 800, V6 / V7

Build 09-60913.

Keywords: Looping a innovaphone PBX behind a Nortel Meridian option 11c

More Information

Problem Details

If we loop a Innovaphone PBX behind a Nortel PBX, we have often a problem with no way audio channel. The problem is that the Nortel PBX used the timeslot 16 with the Channel 31. The Timeslot 16 is for the signalling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signalling.


QSIG-PRI-ECMA1 CR Length 2 Timeslots(1-15,17-31)

Configuration of the Innovaphone Pri Interface

  • Configuration / Pri / Protocol / QSIG ECMA1
  • Configuration / Pri / Interop :
    • all Options disabled and CR Length, CHI Type default


Configuration of the Nortel Pri Interface

Please find below the Nortel D Channel configuration used for Innovaphone VoIP integration.


Settings of the Nortel Meridian option 11c:

  • PT2000,
  • REQ prt,
  • TYPE adan dch 12,
  • ADAN DCH 12,
  • CTYP MSDL,
  • CARD 02,
  • PORT 1,
  • DES QSIG,
  • USR PRI,
  • DCHL 2,
  • OTBF 32,
  • PARM RS422 DTE,
  • DRAT 64KC,
  • CLOK EXT,
  • IFC ISIG,
  • ISDN_MCNT 300,
  • CLID OPT0,
  • CO_TYPE STD,
  • SIDE USR,
  • CNEG 1,
  • RLS ID **,
  • QCHID NO, ------- QCHID is YES by default. Change it to NO to make timeslot values 17 to 31 of the PR12 loop associated with channel numbers 16 to 30 of the Channel Identification IE
  • RCAP NCT COLP,
  • MBGA NO,
  • OVLR NO,
  • OVLS NO,
  • T310 120,
  • T200 3,
  • T203 10,
  • N200 3,
  • N201 260,
  • K 7,

Related Articles