If we loop a Innovaphone PBX behind a Nortel PBX, we have often a Problem with no way audio channel. The Problem is that the Nortel PBX used the Timeslot 16 with the Channel 31. The Timeslot 16 is for the Signaling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signaling
If we loop a Innovaphone PBX behind a Nortel PBX, we have often a problem with no way audio channel. The problem is that the Nortel PBX used the timeslot 16 with the Channel 31. The Timeslot 16 is for the signalling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signalling.




Line 16: Line 16:


===Configuration of the Innovaphone Pri Interface===
===Configuration of the Innovaphone Pri Interface===
Configuration / Pri / Protocol / QSIG ECMA1
Configuration / Pri / Interop :


all Options diabled
*Configuration / Pri / Protocol / QSIG ECMA1
and CR Length ,CHI Type default
*Configuration / Pri / Interop :
**all Options disabled and CR Length, CHI Type default




Line 29: Line 28:




PT2000,
*PT2000,
REQ prt,
*REQ prt,
TYPE adan dch 12,
*TYPE adan dch 12,
ADAN DCH 12,
*ADAN DCH 12,
CTYP MSDL,
*CTYP MSDL,
CARD 02,
*CARD 02,
PORT 1,
*PORT 1,
DES QSIG,
*DES QSIG,
USR PRI,
*USR PRI,
DCHL 2,
*DCHL 2,
OTBF 32,
*OTBF 32,
PARM RS422 DTE,
*PARM RS422 DTE,
DRAT 64KC,
*DRAT 64KC,
CLOK EXT,
*CLOK EXT,
IFC ISIG,
*IFC ISIG,
ISDN_MCNT 300,
*ISDN_MCNT 300,
CLID OPT0,
*CLID OPT0,
CO_TYPE STD,
*CO_TYPE STD,
SIDE USR,
*SIDE USR,
CNEG 1,
*CNEG 1,
RLS ID **,
*RLS ID **,


QCHID NO ---------  '''By default this will be YES.Changed this to NO to make Timeslot values 17 to 31 of the PR12 loop associated with channel number 16 to 30 of the Channel Identification IE''',
*QCHID NO ---------  '''By default this will be YES.Changed this to NO to make Timeslot values 17 to 31 of the PR12 loop associated with channel number 16 to 30 of the Channel Identification IE''',


RCAP NCT COLP,
*RCAP NCT COLP,
MBGA NO,
*MBGA NO,
OVLR NO,
*OVLR NO,
OVLS NO,
*OVLS NO,
T310 120,
*T310 120,
T200 3,
*T200 3,
T203 10,
*T203 10,
N200 3,
*N200 3,
N201 260,
*N201 260,
K 7,
*K 7,


 
== Related Articles ==
 
[[Howto:Looping in a innovaphone Gateway]]
Related Articles : Howto:Looping in a innovaphone Gateway


[[Category:Howto|{{PAGENAME}}]]
[[Category:Howto|{{PAGENAME}}]]

Revision as of 17:06, 6 April 2009

Applies To

This information applies to

  • IP 6000,IP3000 V6/ V7
  • IP 800, V6 / V7

Build 09-60913.

Keywords: Looping a innovaphone PBX behind a Nortel Meridian option 11c

More Information

Problem Details

If we loop a Innovaphone PBX behind a Nortel PBX, we have often a problem with no way audio channel. The problem is that the Nortel PBX used the timeslot 16 with the Channel 31. The Timeslot 16 is for the signalling in the QSIG Protocol. Innovaphone use the Timeslot 16 with the channel 17 for the signalling.


QSIG-PRI-ECMA1 CR Length 2 Timeslots(1-15,17-31)

Configuration of the Innovaphone Pri Interface

  • Configuration / Pri / Protocol / QSIG ECMA1
  • Configuration / Pri / Interop :
    • all Options disabled and CR Length, CHI Type default


Configuration of the Nortel Pri Interface

Please find below the Nortel D Channel configuration used for Innovaphone VoIP integration.

Settings from the Nortel Meridian option 11c.


  • PT2000,
  • REQ prt,
  • TYPE adan dch 12,
  • ADAN DCH 12,
  • CTYP MSDL,
  • CARD 02,
  • PORT 1,
  • DES QSIG,
  • USR PRI,
  • DCHL 2,
  • OTBF 32,
  • PARM RS422 DTE,
  • DRAT 64KC,
  • CLOK EXT,
  • IFC ISIG,
  • ISDN_MCNT 300,
  • CLID OPT0,
  • CO_TYPE STD,
  • SIDE USR,
  • CNEG 1,
  • RLS ID **,
  • QCHID NO --------- By default this will be YES.Changed this to NO to make Timeslot values 17 to 31 of the PR12 loop associated with channel number 16 to 30 of the Channel Identification IE,
  • RCAP NCT COLP,
  • MBGA NO,
  • OVLR NO,
  • OVLS NO,
  • T310 120,
  • T200 3,
  • T203 10,
  • N200 3,
  • N201 260,
  • K 7,