Howto:Master - Slave Numbering Scheme with one Node and more Pbx/Locations
Applies To
This information applies to
- IP 6000, V6
- IP 3000, V6
- IP 800, V6
- IP 305, V6
- IP 302, V6
- IP 202, V6
Build 06-60400.31 or later
More Information
How to configure a Numbering Node with one Node and more Pbx/Locations
Having more innovaphone locations. On every site (location) is an innovaphone
Gateway with Isdn connection (Local Isdn Trunk) and one virtual Pbx over all locations.
That means every number in this location concept is uniqe.
Every Endpoint dials only the number of any phone in any location.
Also every Endpoint dials the trunk line Number (e.g 0) and gets a local break out.
General Explanation of the numbering node and Pbx
go to Howto:Description of the Numbering Scheme used in V6
Problem Details
IF for every remote location a local isdn breakout is needed –
therefore it takes a little tricky configuration.
Configuration
Configuring the Master Pbx
Pbx Mode Master
System Name is the Gatekeeper Id (AT01)
And the Pbx name (A)
Here you define the pbx name , later in the user objects you configure on what Pbx (pbx name) the phones should register.
Registering/Configuring Endpoints (e.g Phones) on the Master Pbx.
User Object
The node: You can have different nodes on one Gateway (Pbx) to have more virtual Pbx.
For example having same extensions.
Also you can have one node per Pbx
The node root is the upper tree node, all other nodes are below the root node – this are
all own virtual Pbx. So if in a node a number is not found it will go to the upper node .
On the Pbx field you define on what Pbx the Phones register, here it is the local
Pbx (A).
Then you have to define the Pbx of the remote Location in the Master