Howto:Master - Slave numbering node with X nodes and X pbx
How to configure numbering node with X nodes and X pbx.
Applies To
This information applies to
- IP 6000, V6
- IP 3000, V6
- IP 800, V6
- IP 305, V6
- IP 302, V6
- IP 202, V6
Build 06-60400.87 or later
More Information
General explanation of the node and pbx – numbering node schema (formerly known as locations concept)
Go to http://www.innovaphone.com/inno-kb/article.aspx?id=10670
The szenario and configuration way described here
Having more innovaphone locations. On every site (location) is an innovaphone gateway with Isdn connection (local Isdn trunk) and more nodes over all locations. That means it is possible to have same phone extensions over different nodes. Every endpoint dials only the extension in-between the own node- if its to reach another node the prefix of this node has to be dialed too.
Also every endpoint dials the trunk line number (e.g 0) and gets a local break out.
System Requirements
At least 2 innovaphone gateways with activated pbx (basic lic on every gateway and pbx lic only on every gateway). Also Isdn and DSP lics for the Isdn local breakout and innovaphone Phones/Endpoints J
Configuration
Configuring the master pbx
Pbx mode master
System name is the Gatekeeper Id (AT01)
And the pbx name (A).
Here you define the pbx name , later in the user objects you configure on what physical pbx (pbx name) the phones should register.
Configuring the node with prefix
Long name /name – define the name of this node/location, and the number 100 here is the prefix for this node/location.
Registering/Configuring endpoints on the master pbx
The node: The endpoint is in node A therefore choose the node Anode
The node root is the upper tree node, all other nodes are below the root node – this are all own virtual pbx. So if in a node a number is not found it will go to the upper node. On the pbx field you define on what pbx the phones register, here it is the local pbx (A).
When registering an endpoint to Anode you have to put the prefix also in the registration on the phone. So in this case you have to configure in the phone the number 100101.
Then you have to define the pbx of the remote node (location) at the master.
The name and long name is the same as the pbx name on the remote location.
Node is the root and the pbx is the master pbx (A), Password is not needed, if you take a password then you have to configure this in the slave pbx also.
(andminstration/pbx/general slave pbx password)
The number here is 200 ,so the prefix for node B is 200
Trunk user for node A
The trunk user must be also in the Anode
As the phones in the A node dialing the 0 they get dropped out via this trunk object.