Howto:Power Consumption: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
|||
Line 34: | Line 34: | ||
|} | |} | ||
==Power level of | ==Power level of innovaphone devices== | ||
Gateways: | Gateways: | ||
{| border=1 | {| border=1 | ||
Line 40: | Line 40: | ||
|Device | |Device | ||
|PoE-Class | |PoE-Class | ||
| | |average total input power [mW]* | ||
| | |max total input power [mW]* | ||
|- | |- | ||
|IP22 | |IP22 | ||
|3 | |3 | ||
| | |3000 | ||
| | |4600 | ||
|- | |- | ||
|IP24 | |IP24 | ||
|3 | |3 | ||
| | |3600 | ||
| | |6800 | ||
|- | |- | ||
|IP28 | |IP28 | ||
|3 | |3 | ||
| | |4000 | ||
| | |12900 | ||
|- | |- | ||
|IP302 | |IP302 | ||
|3 | |3 | ||
| | |3000 | ||
| | |4800 | ||
|- | |- | ||
|IP305 | |IP305 | ||
|2 | |2 | ||
| | |2900 | ||
| | |3000 | ||
|- | |- | ||
|IP800 up to HW201 | |IP800 up to HW201 | ||
Line 76: | Line 75: | ||
|IP800 ex HW300 | |IP800 ex HW300 | ||
|3 | |3 | ||
| | |4700 | ||
| | |10500 | ||
|- | |- | ||
|IP2000 | |IP2000 | ||
|3 | |3 | ||
| | |5900 | ||
| | |6500 | ||
|- | |- | ||
|IP6000 | |IP6000 | ||
|3 | |3 | ||
| | |9800 | ||
| | |10000 | ||
|- | |- | ||
|IP1200 | |IP1200 | ||
|0 | |0 | ||
| | |5000 | ||
| | |8000 | ||
|- | |- | ||
|} | |} | ||
Line 101: | Line 100: | ||
|Device | |Device | ||
|PoE-Class | |PoE-Class | ||
| | |max total input power [mW]* | ||
| | |average total input power [mW]* | ||
|- | |- | ||
|IP110 | |IP110 | ||
|1 | |1 | ||
| | |2500 | ||
| | |2700 | ||
|- | |- | ||
|IP200A | |IP200A | ||
|1 | |1 | ||
| | |2900 | ||
| | |3200 | ||
|- | |- | ||
|IP230 | |IP230 | ||
|2 | |2 | ||
| | |2600 | ||
| | |2900 | ||
|- | |- | ||
|IP240 | |IP240 | ||
|2 | |2 | ||
| | |3100 | ||
| | |3800 | ||
|- | |- | ||
|IP150 | |IP150 | ||
Line 131: | Line 130: | ||
|IP240-1000 | |IP240-1000 | ||
|2 | |2 | ||
| | |4900 | ||
| | |5900 | ||
|- | |- | ||
|IP230-x | |IP230-x | ||
|extension module | |extension module | ||
| | |1000 | ||
| | |1000 | ||
|- | |- | ||
|} | |} | ||
*These values were averaged results from simulating normal and maximum use. | |||
To have an official max total input power value please orientate on the upper limit of the associated PoE class. | |||
Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X | Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X |
Revision as of 16:51, 16 September 2008
Power level
The power consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
Class | Usage | Power level PSE [W] | Power level PD [W] |
0 | default | 15,4 | 0,44 - 12,95 |
1 | optional | 4 | 0,44 - 3,84 |
2 | optional | 7 | 3,84 - 6,49 |
3 | optional | 15,4 | 6,49 - 12,95 |
4 | reserved | 15,4 | 0,44 - 12,95 |
Power level of innovaphone devices
Gateways:
Device | PoE-Class | average total input power [mW]* | max total input power [mW]* |
IP22 | 3 | 3000 | 4600 |
IP24 | 3 | 3600 | 6800 |
IP28 | 3 | 4000 | 12900 |
IP302 | 3 | 3000 | 4800 |
IP305 | 2 | 2900 | 3000 |
IP800 up to HW201 | 0 | ||
IP800 ex HW300 | 3 | 4700 | 10500 |
IP2000 | 3 | 5900 | 6500 |
IP6000 | 3 | 9800 | 10000 |
IP1200 | 0 | 5000 | 8000 |
Phones:
Device | PoE-Class | max total input power [mW]* | average total input power [mW]* |
IP110 | 1 | 2500 | 2700 |
IP200A | 1 | 2900 | 3200 |
IP230 | 2 | 2600 | 2900 |
IP240 | 2 | 3100 | 3800 |
IP150 | 1 | ||
IP240-1000 | 2 | 4900 | 5900 |
IP230-x | extension module | 1000 | 1000 |
*These values were averaged results from simulating normal and maximum use. To have an official max total input power value please orientate on the upper limit of the associated PoE class.
Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X
5.9W +3*1W= 8.9W
Estimated worst case power consumption for operation of a 240 with 3 IP230-X
3.8W +3*1W= 6.8W