Howto:Power Consumption
Jump to navigation
Jump to search
Power level
The power consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
Class | Usage | Power level PSE [W] | Power level PD [W] |
0 | default | 15,4 | 0,44 - 12,95 |
1 | optional | 4 | 0,44 - 3,84 |
2 | optional | 7 | 3,84 - 6,49 |
3 | optional | 15,4 | 6,49 - 12,95 |
4 | reserved | 15,4 | 0,44 - 12,95 |
Power level of innovaphone devices
Gateways:
Device | PoE-Class | average total input power [mW]* | max total input power [mW]* |
IP22 | 3 | 3000 | 4600 |
IP24 | 3 | 3600 | 6800 |
IP28 | 3 | 4000 | 12900 |
IP302 | 3 | 3000 | 4800 |
IP305 | 2 | 2900 | 3000 |
IP800 up to HW201 | 0 | ||
IP800 ex HW300 | 3 | 4700 | 10500 |
IP2000 | 3 | 5900 | 6500 |
IP6000 | 3 | 9800 | 10000 |
IP1200 | 0 | 5000 | 8000 |
Phones:
Device | PoE-Class | max total input power [mW]* | average total input power [mW]* |
IP110 | 1 | 2500 | 2700 |
IP200A | 1 | 2900 | 3200 |
IP230 | 2 | 2600 | 2900 |
IP240 | 2 | 3100 | 3800 |
IP150 | 1 | ||
IP240-1000 | 2 | 4900 | 5900 |
IP230-x | extension module | 1000 | 1000 |
*These values were averaged results from simulating normal and maximum use. To have an official max total input power value please orientate on the upper limit of the associated PoE class.
Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X
5.9W +3*1W= 8.9W
Estimated worst case power consumption for operation of a 240 with 3 IP230-X
3.8W +3*1W= 6.8W