General Gateway Settings

Gatekeeper ID The Gatekeeper Identifier. This is used with VOIP interfaces configured as "Gatekeeper/Registrar" as Gatekeeper Identifier (H.323) or Registrar Name (SIP). If multiple Gatekeepers are installed in a network this can be used to find the right gatekeeper using gatekeeper discovery. If a PBX is enabled on the same system a different Gatekeeper Identifier must be used for Gateway and PBX.
Call Logging A checked check box enables the output of syslog information in respect of the calls made via the gateway.
Route Logging A checked check box enables the output of syslog information in respect of the used voice routes of the gateway.
Billing CDRs only If enabled for each call only a single record at the end of the call is send as CDR. This record contains all information needed for billing purposes.

Feature Codes

If any interface with activated feature codes is configured a table to configure the feature codes is displayed. These feature codes are the same for all interfaces in the system. See Howto:Feature Codes for a description of available features.

Licenses

This table displays the installed licenses and the current use of these licenses.

Gateway Valid only if this is an OEM version of the gateway, which by default does not have "Gateway" capabilities. If there are no Gateway capabilities the Interfaces can only be used for a local PBX.
Gatekeeper6 Gatekeeper licences. Allows VOIP Interfaces of type "Gatekeeper /Registrar" to be configured.
BRIs Basic Rate ISDN interfaces. The available licenses are used for the interfaces in the sequence the interfaces are displayed. To use other interfaces it is possible to disable interfaces
PRIs Primary Rate ISDN interfaces. The available licenses are used for the interfaces in the sequence the interfaces are displayed. To use other interfaces it is possible to disable interfaces
Channels DSP channels.
ABs Analog interfaces.