Reference:Configuration/DECT/Master: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
mNo edit summary |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
'''Note''': This information applies to IP1200 | |||
It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated. | It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated. | ||
Line 5: | Line 7: | ||
** '''Active''' switches on the DECT master function. | ** '''Active''' switches on the DECT master function. | ||
** '''Standby''' switches on the standby function for the DECT master. | ** '''Standby''' switches on the standby function for the DECT master. | ||
* '''Primary Master IP Address:''' This field is only visible if this device has been | * '''Primary Master IP Address:''' This field is only visible if this device has been configured as Standby-Master ('''''Mode'' = ''Standby'''''). The IP address of the DECT-Master has to be configured here. | ||
* '''GK:''' The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated. | * '''GK:''' The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated. | ||
* '''Alt GK:''' The IP address of the secondary, alternative gatekeeper. | * '''Alt GK:''' The IP address of the secondary, alternative gatekeeper. | ||
* '''GK ID:''' The gatekeeper ID of the gatekeeper to be used. | * '''GK ID:''' The gatekeeper ID of the gatekeeper to be used. It is required to configure a gatekeeper ID if in the DECT Master device a PBX is also active. | ||
* '''Prot:''' The protocol to be used for the communication. There is a choice between: | * '''Prot:''' The protocol to be used for the communication. There is a choice between: | ||
** '''H.323''' (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features. | ** '''H.323''' (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features. | ||
Line 14: | Line 16: | ||
* '''STUN Server:''' STUN server to be used if DECT master has no public ip address and SIP server is outside the local network. | * '''STUN Server:''' STUN server to be used if DECT master has no public ip address and SIP server is outside the local network. | ||
* '''Name for Authentication:''' Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication. | * '''Name for Authentication:''' Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication. | ||
* ''' | * '''Redirection with GK ID''' If enabled and the user registration is redirected, the GK ID of the redirecting PBX is appended to the registration to the redirected PBX. | ||
* '''Enbloc Dialing''' If enabled, the dialed numbers will be sent together within the setup message after timeout. | |||
* '''Allow DTMF through RTP''' If enabled, DTMF capability through RTP is allowed. | |||
* '''Enable messaging to PBX''' Message will be send via SIP or H.323, if disabled messages will be sent via the Polycom MSF-Module. | |||
* '''Idle Display Update''' Enables idle display updates. | |||
* '''Disable broadcast delay''' For small installations it is not necessary to delay the broadcasts for incoming calls to the radios. Enabling this option is not recommended for big systems. |
Latest revision as of 09:38, 14 May 2012
Note: This information applies to IP1200
It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated.
- Mode: Active switches on the DECT master function. In every DECT system, there must be a DECT master.
- Off switches off the DECT master function.
- Active switches on the DECT master function.
- Standby switches on the standby function for the DECT master.
- Primary Master IP Address: This field is only visible if this device has been configured as Standby-Master (Mode = Standby). The IP address of the DECT-Master has to be configured here.
- GK: The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated.
- Alt GK: The IP address of the secondary, alternative gatekeeper.
- GK ID: The gatekeeper ID of the gatekeeper to be used. It is required to configure a gatekeeper ID if in the DECT Master device a PBX is also active.
- Prot: The protocol to be used for the communication. There is a choice between:
- H.323 (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features.
- SIP (RFC 3261).
- STUN Server: STUN server to be used if DECT master has no public ip address and SIP server is outside the local network.
- Name for Authentication: Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication.
- Redirection with GK ID If enabled and the user registration is redirected, the GK ID of the redirecting PBX is appended to the registration to the redirected PBX.
- Enbloc Dialing If enabled, the dialed numbers will be sent together within the setup message after timeout.
- Allow DTMF through RTP If enabled, DTMF capability through RTP is allowed.
- Enable messaging to PBX Message will be send via SIP or H.323, if disabled messages will be sent via the Polycom MSF-Module.
- Idle Display Update Enables idle display updates.
- Disable broadcast delay For small installations it is not necessary to delay the broadcasts for incoming calls to the radios. Enabling this option is not recommended for big systems.