Line 14: Line 14:
* '''HTTP:''' The syslog entries are transferred to a Web server, where they can be further processed. Each individual syslog entry is transferred as form data to the Web server in HTTP GET format.
* '''HTTP:''' The syslog entries are transferred to a Web server, where they can be further processed. Each individual syslog entry is transferred as form data to the Web server in HTTP GET format.
<blockquote>
<blockquote>
* In the Address field, the IP-Adresse of the Web server that carries out further processing of the transmitted data is entered.<br>
* In the Address field, the IP-Adresse of the Web server that carries out further processing of the transmitted data is entered.
* In the Path field, the relative URL of the form program on the Web server is entered.
* In the Path field, the relative URL of the form program on the Web server is entered.
</blockquote>
</blockquote>
The device will make a HTTP GET request to the Web server on the entered URL, followed by the URL-encoded syslog entry. If, for example, a page named /cdr/cdrwrite.asp with a form that expects the log message in parameter msg exists on a Web server, then the value /cdr/cdrwrite.asp is entered. The device will then make a GET /cdr/cdrwrite.asp?event=syslog&msg=logmsg request to the Web server.
The device will make a HTTP GET request to the Web server on the entered URL, followed by the URL-encoded syslog entry. If, for example, a page named /cdr/cdrwrite.asp with a form that expects the log message in parameter msg exists on a Web server, then the value /cdr/cdrwrite.asp is entered. The device will then make a GET /cdr/cdrwrite.asp?event=syslog&msg=logmsg request to the Web server.

Revision as of 17:31, 3 April 2007

External logging is disabled as standard (Off). After selection of a log type, logging is enabled, as are the relevant entry fields.

  • Off: Logging is disabled.
  • TCP: The device transmits the syslog entries using a TCP (Transmission Control Protocol) connection.
  • In the Address field, the IP-Adresse at which the TCP connection is to be set up is entered.
  • In the Port field, the port to which the connection is set up is specified.
  • SYSLOG: The syslog entries are transmitted to a syslog recipient (also referred to as syslogd, syslog server or syslog daemon ), which is then responsible for their further evaluation or storage.
  • In the Address field, the IP address of the syslogd server is entered.
  • In the Class field, the desired message class that will be responsible for further processing of the syslog entries is entered. The syslog class is a numeric value between 0 and 7.
  • HTTP: The syslog entries are transferred to a Web server, where they can be further processed. Each individual syslog entry is transferred as form data to the Web server in HTTP GET format.
  • In the Address field, the IP-Adresse of the Web server that carries out further processing of the transmitted data is entered.
  • In the Path field, the relative URL of the form program on the Web server is entered.

The device will make a HTTP GET request to the Web server on the entered URL, followed by the URL-encoded syslog entry. If, for example, a page named /cdr/cdrwrite.asp with a form that expects the log message in parameter msg exists on a Web server, then the value /cdr/cdrwrite.asp is entered. The device will then make a GET /cdr/cdrwrite.asp?event=syslog&msg=logmsg request to the Web server.