Performance counters are calculated once per minute (that is: one pixel in the graph represents a minute). However they are saved to flash only each full hour, so counter values calculated prior to a trap may be missing.

The CPU-counter calculates the mean value each 10 seconds. Since only every 60 seconds a pixel in the graph is drawn, the highest value of the 6 measured values in this minute is used.