Reference:Configuration/ETH/Link: Difference between revisions
m table added |
mNo edit summary |
||
| Line 1: | Line 1: | ||
The transmission mode of the Ethernet interface is defined here. | The transmission mode of the Ethernet interface is defined here. On phones with a configurable switch the PC and the LAN port can be configured. | ||
== Configuration == | == Configuration == | ||
| Line 23: | Line 23: | ||
== Status == | == Status == | ||
In addition, the status of the interface (''Up'' or ''Down'') and the Autonegation used (for example, 100m-fdx) are displayed. | In addition, the status of the interface (''Up'' or ''Down'') and the Autonegation used (for example, 100m-fdx) are displayed. | ||
== Ethernet MDX == | |||
IP400, IP21 and IP3000 the ethernet interface has a switch to configure the port to be connected to a hub/switch or terminal. | |||
On gateways with 2 ethernet interfaces ETH0 can be connected directly to a switch port, ETH1 can be connected directly to terminal. Other connections are possible if auto-MDX is supported in the switch or in the gateway or if a crossover cable is used. | |||
IP800 (hardwarebuild below 108) and IP6000 (hardwarebuild below 200) and IP21 support Auto-MDX. | |||
Revision as of 14:15, 27 August 2007
The transmission mode of the Ethernet interface is defined here. On phones with a configurable switch the PC and the LAN port can be configured.
Configuration
The auto transmission mode is pre-selected:
| auto: | Automatic selection of the transmission speed. |
| 10m-hdx: | Corresponds to 10 MBit Half Duplex. |
| 10m-fdx: | Corresponds to 10 MBit Full Duplex. |
| 100m-hdx: | Corresponds to 100 MBit Half Duplex. |
| 100m-fdx: | Corresponds to 100 MBit Full Duplex. |
Status
In addition, the status of the interface (Up or Down) and the Autonegation used (for example, 100m-fdx) are displayed.
Ethernet MDX
IP400, IP21 and IP3000 the ethernet interface has a switch to configure the port to be connected to a hub/switch or terminal.
On gateways with 2 ethernet interfaces ETH0 can be connected directly to a switch port, ETH1 can be connected directly to terminal. Other connections are possible if auto-MDX is supported in the switch or in the gateway or if a crossover cable is used.
IP800 (hardwarebuild below 108) and IP6000 (hardwarebuild below 200) and IP21 support Auto-MDX.