Line 414: | Line 414: | ||
* IP230/IP24x plus up to three IP230-X: a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231) | * IP230/IP24x plus up to three IP230-X: a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231) | ||
* IP2x2 plus up to two IP2x2x: same as above - a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231) | * IP2x2 plus up to two IP2x2x: same as above - a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231) | ||
* IP2x2 plus one IP2x2x: POE Class 2 is sufficient if no other USB loads are present | |||
===40V PSU for IP adapters and gateways=== | ===40V PSU for IP adapters and gateways=== |
Revision as of 15:16, 7 October 2022
Supply via Power over Ethernet (PoE)
Power level
The power consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
Class | Usage | Power level PSE [W] | Power level PD [W] |
0 | default | 15,4 | 0,44 - 12,95 |
1 | optional | 4 | 0,44 - 3,84 |
2 | optional | 7 | 3,84 - 6,49 |
3 | optional | 15,4 | 6,49 - 12,95 |
4 | optional | 30 | 12,95-25,5 W (802.3at/Typ 2) |
Power level of innovaphone devices
Gateways:
Device | PoE-Class | average total input power [mW]* | max total input power [mW]* |
IP22 | 3 | 3000 | 4600 |
IP24 | 3 | 3600 | 6800 |
IP28 | 3 | 4000 | 12900 |
IP38 | 1 | 2800 | 3800 |
IP302 | 3 | 3000 | 4800 |
IP305 | 2 | 2900 | 3000 |
IP800 up to HW201 | 0 | ||
IP800 ex HW300 | 3 | 4700 | 10500 |
IP2000 | 3 | 5900 | 6500 |
IP6000 | 3 | 9800 | 10000 |
IP1200 | 0 | 5000 | 8000 |
IP1202/IP1203 | 2 | 5000 | |
IP0010 | 3 | 8000 | 12500 |
IP3010 | 3 | 8000 | 12500 |
IP6010 | 3 | 8000 | 12500 |
IP1060 | 3 | 8000 | 12500 |
IP810 | 3 | 8000 | 12500 |
IP311/IP411/IP811/IP29/IP0011 | 3 | 5000 | 12500 |
IP1130/IP3011 | 3 | 8000 | 12500 |
IP29-2/4/8 | 3 | May vary in dependency of FXS usage. | 12500 |
IP29-20 | 4 | May vary in dependency of FXS usage. | 25500 |
IP6013 | 4 | n.a. | 25500 |
Phones:
Device | PoE-Class | idle state [mW]**** | average total input power [mW]* | max total input power [mW]* | manufacturing check [mW]** |
IP110 | 1 | 2500 | 2700 | 3500 | |
IP200A | 1 | 2900 | 3200 | 3500 | |
IP230 | 2 | 2600 | 2900 | 3500 | |
IP240 | 2 | 3100 | 3800 | 4000 | |
IP150 | 1 | 2800 | 3000 | 3500 | |
IP240-1000 | 2 | 4900 | 5900 | 6500 | |
IP230-x | extension module | 1000 | 1000 | ||
IP241 | HW < 402 = 3
HW >= 402 = 2 |
2400 | < 3500 | ||
IP222 | 2 | 2500 | 4800*** | ||
IP232 | 2 | 2600 | 4900*** | ||
IP111(A) | 1 | 1400 | 2000 | 3800 | 2500 |
IP112(A) | 2 | 1800 | 2100 | 4000 | 2500 |
IP101 | 1 | 2000 | |||
IP102 | 2 | 3500 |
*These values were averaged results from simulating normal and maximum use. To have an official max total input power value please orientate on the upper limit of the associated PoE class.
**All devices leaving the manufacturing process are checked whether the cunsumption is under this value.
***LAN and PC interface connected with 1Gbit/s. 4xUSB connected (only IP2x2).
****LAN connected with 100Mbit/s. PC not connected. EEE active if supported. LCD light (idle state) == 0
Estimated worst case power consumption for operation of a 240-1000 with 3 IP230-X
5.9W +3*1W= 8.9W
Estimated worst case power consumption for operation of a 240 with 3 IP230-X
3.8W +3*1W= 6.8W
PoE Injector Capacity
All PoE injectors offered by innovaphone (order code 03-00010-228 and 03-00010-231) fullfill the power demand PoE capable innovaphone devices need (generally 15W at PSE side). This is good for any device up to PoE class 3.
Supply via Power Supply Unit (PSU)
Most of the innovaphone devices can be supplied by an external PSU (exception: IP800; IP2000; IP6000 with build in power supply). All testreadings were determined by measuring the power consumption of the PSU. They are no official numbers. The following tables are showing different phone modes. All values in mW.
12V PSU for phones
Without using switch functionality (only LAN is connected 100Mbit/s):
Device | Standby | On-Hook | Active (handsfree with max loudness) | Ringing |
IP110 | 2900 | 3000 | 3400 | 3000 |
IP200A | 3400 | 3500 | 3900 | 3500 |
IP230 | 3000 | 3300 | 3500 | 3300 |
IP240 | 3400 | 3700 | 3800 | 3700 |
IP240-1000 | 5200 | 5500 | 5700 | 5500 |
IP241 | < 3500 | |||
IP222 | 2500 | |||
IP232 | 2600 |
Using switch functionality (PC + LAN is connected 100Mbit/s):
Device | Standby | On-Hook | Active (handsfree with max loudness) | Ringing |
IP110 | 3300 | 3400 | 3700 | 3400 |
IP200A | 3900 | 3900 | 4400 | 3900 |
IP230 | 3400 | 3600 | 3800 | 3600 |
IP240 | 3800 | 4100 | 4200 | 4100 |
IP240-1000 | 7400 | 7700 | 7900 | 7700 |
IP241 | 4500*** | |||
IP222 | 4200*** | |||
IP232 | 4300*** |
Use of extension modules
- IP230/IP24x plus up to three IP230-X: a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231)
- IP2x2 plus up to two IP2x2x: same as above - a more efficient PSU is needed. Please use the 40V Gateway PSU or PoE injector from innovaphone (order no 03-00010-231)
- IP2x2 plus one IP2x2x: POE Class 2 is sufficient if no other USB loads are present
40V PSU for IP adapters and gateways
Note as of May 2018: This product is End-of-life and no more offered by innovaphone.
The 40V PSU (order no. 03-00010-226) can be used for all gateways and adapters with small housing. In detail these are IP22, IP24, IP28, IP38, IP302 and IP305.
Releated notes
Heat output (BTU)
Sometimes we receive inquiries about the heat output (BTU - British Thermal Unit) of our devices.
innovaphone itself does not provide any information about this.
With afore mentioned power consumption values (! units are in mW) and corresponding converters (e.g. here), the BTU can be calculated on your own responsibility.