Power level
The consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
| Class | Usage | Power level PSE [W] | Power level PE [W] |
| 0 | default | 15,4 | 0,44 - 12,95 |
| 1 | optional | 4 | 0,44 - 3,84 |
| 2 | optional | 7 | 3,84 - 6,49 |
| 3 | optional | 15,4 | 6,49 - 12,95 |
| 4 | reserved | 15,4 | 0,44 - 12,95 |
Power level of Innovaphone devices
Gateways:
| Device | PoE-Class |
| IP22 | 3 |
| IP24 | 3 |
| IP28 | 3 |
| IP302 | 3 |
| IP305 | 2 |
| IP800 | 3 |
| IP2000 | 3 |
| IP6000 | 3 |
Phones:
| Device | PoE-Class |
| IP110 | 1 |
| IP200A | 1 |
| IP230 | 1 |
| IP230 + IP230X | 2 |
| IP240 |