Howto:Power Consumption
Jump to navigation
Jump to search
Power level
The power consumption of PoE devices is separated into several classes for power sourcing equipment (PSE) and the powered device (PD).
Class | Usage | Power level PSE [W] | Power level PD [W] |
0 | default | 15,4 | 0,44 - 12,95 |
1 | optional | 4 | 0,44 - 3,84 |
2 | optional | 7 | 3,84 - 6,49 |
3 | optional | 15,4 | 6,49 - 12,95 |
4 | reserved | 15,4 | 0,44 - 12,95 |
Power level of Innovaphone devices
Gateways:
Device | PoE-Class | maximail Watt | usual Watt |
IP22 | 3 | ||
IP24 | 3 | ||
IP28 | 3 | ||
IP302 | 3 | ||
IP305 | 2 | ||
IP800 up to HW201 | 0 | ||
IP800 ex HW300 | 3 | ||
IP2000 | 3 | ||
IP6000 | 3 | ||
IP1200 | 0 | 8 | 5 |
Phones:
Device | PoE-Class |
IP110 | 1 |
IP200A | 1 |
IP230 | 2 |
IP240 | 2 |
IP150 | 1 |