Reference14r1:Settings/Phone settings/Device settings
There are also other versions of this article available:
Reference7 | Reference14r1 (this version)
- Headset
- Enable/Disable headset support
- LCD light
- Set current display brightness. 0 (off) - 15 (max). Default 8.
- LCD light (idle state)
- Display brightness applied 30s after last action. 0 (off) - 15 (max). Default 2.
- To prevent display dimming, set LCD light and LCD light (idle state) to same level
- Energy saving
- Time frame in which the display is switched off instead of being dimmed if in idle state. Format <starthours>-<endhours> in 24h-notation with leading zeros. E.g. 17-09 turns off display between 17 o'clock (5pm) until 9 o'clock (9am). Default is 22-06.
- To prevent switching off the display, set Energy saving to 00-00.
Configuration entries for automated deployment
- LCD light
vars create PHONE/LCD-BACKLIGHT p 8
- LCD light (idle state)
vars create PHONE/LCD-IDLE-BACKLIGHT p 2
- Energy saving
vars create PHONE/ENERGY-SAVING-TIME p 22-06
Example to be used in Devices configuration/Expert configuration
- Use the check command as in the example below to prevent re-execution every 30 seconds
#Use Check command to prevent execution loops mod cmd UP1 check iresetn Energie-Saving vars create PHONE/LCD-BACKLIGHT p 8 vars create PHONE/LCD-IDLE-BACKLIGHT p 2 vars create PHONE/ENERGY-SAVING-TIME p 22-07 ser