Reference7:Administration/PBX/Objects/icp
The ICP object will be mainly used in scandivia for presence information. ICP stands for Interception Computer Protocol, which is used to transfer presence information about users between different applications. One scenerio is an operator with trio software and an ip6000, which connects to the trio server to exchange presence information.
Configuration
The configuration interface looks like this:
As each object, the icp object must have a name.
Number
The number to call, if presence should be activated for a user.
Canceling e164
The number to call, if presence should be deactivated for a user.
Deactivation Type
There are two options: Meridian and MD110. The protocol differences between two deactivation messages. One for Meridian (message type 57) and one for MD110 (message type 58). You have to determine, which type your icp system uses.
icp diversion e164
The number to which callers are diverted to, if a user has activated presence information.
Present System
If an ip is given here (dns is notsupported), the box tries to connect to this icp present system. If no ip is given, the box awaits connection on the specified port.
Port
The port, on which the connection gets established.
Terminal ID Len
The maximum terminal ID Len. Must be the same as in your ICP system.
Directory Number Len
The maximum directory number len (e164). Must be the same as in your ICP system.
Fill Character
The fill character for shorter directory/terminal numbers. Must be the same as in your ICP system.
Send Heartbeat
Some ICP systems wait for heartbeats and other send heartbeats. You have to determine, what your system awaits.
Heartbeat Interval
The interval between two heartbeats.