'''Note''': This information applies to IP1200
It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated.
It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated.


* '''Mode:''' Active switches on the DECT master function. In every DECT system, there must be a DECT master.
* '''Mode:''' Active switches on the DECT master function. In every DECT system, there must be a DECT master.
** '''Off''' switches off the DECT master function.
** '''Active''' switches on the DECT master function.
** '''Standby''' switches on the standby function for the DECT master.
** '''Standby''' switches on the standby function for the DECT master.
** '''Off''' switches off the DECT master function.
* '''Primary Master IP Address:''' This field is only visible if this device has been configured as Standby-Master ('''''Mode'' = ''Standby'''''). The IP address of the DECT-Master has to be configured here.
* '''GK:''' The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated.
* '''GK:''' The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated.
* '''Alt GK:''' The IP address of the secondary, alternative gatekeeper.
* '''Alt GK:''' The IP address of the secondary, alternative gatekeeper.
* '''GK ID:''' The gatekeeper ID of the gatekeeper to be used.
* '''GK ID:''' The gatekeeper ID of the gatekeeper to be used. It is required to configure a gatekeeper ID if in the DECT Master device a PBX is also active.
* '''Prot:''' The protocol to be used for the communication. There is a choice between:
* '''Prot:''' The protocol to be used for the communication. There is a choice between:
** '''H.323''' (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features.
** '''H.323''' (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features.
Line 12: Line 16:
* '''STUN Server:''' STUN server to be used if DECT master has no public ip address and SIP server is outside the local network.
* '''STUN Server:''' STUN server to be used if DECT master has no public ip address and SIP server is outside the local network.
* '''Name for Authentication:''' Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication.
* '''Name for Authentication:''' Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication.
* '''Redirection with GK ID''' If enabled and the user registration is redirected, the GK ID of the redirecting PBX is appended to the registration to the redirected PBX.
* '''Enbloc Dialing''' If enabled, the dialed numbers will be sent together within the setup message after timeout.
* '''Allow DTMF through RTP''' If enabled, DTMF capability through RTP is allowed.
* '''Enable messaging to PBX''' Message will be send via SIP or H.323, if disabled messages will be sent via the Polycom MSF-Module.
* '''Idle Display Update''' Enables idle display updates.
* '''Disable broadcast delay''' For small installations it is not necessary to delay the broadcasts for incoming calls to the radios. Enabling this option is not recommended for big systems.

Latest revision as of 09:38, 14 May 2012

Note: This information applies to IP1200

It is necessary to configure the operating mode of the DECT system. A gatekeeper must also be specified here, on which the innovaphone PBX component is operated.

  • Mode: Active switches on the DECT master function. In every DECT system, there must be a DECT master.
    • Off switches off the DECT master function.
    • Active switches on the DECT master function.
    • Standby switches on the standby function for the DECT master.
  • Primary Master IP Address: This field is only visible if this device has been configured as Standby-Master (Mode = Standby). The IP address of the DECT-Master has to be configured here.
  • GK: The IP address of the primary gatekeeper. The device on which the innovaphone PBX component is operated.
  • Alt GK: The IP address of the secondary, alternative gatekeeper.
  • GK ID: The gatekeeper ID of the gatekeeper to be used. It is required to configure a gatekeeper ID if in the DECT Master device a PBX is also active.
  • Prot: The protocol to be used for the communication. There is a choice between:
    • H.323 (RFC 1889), which is the recommended protocol for innovaphone VoIP devices, since it implements most features.
    • SIP (RFC 3261).
  • STUN Server: STUN server to be used if DECT master has no public ip address and SIP server is outside the local network.
  • Name for Authentication: Some SIP PBXs need authentication name different from the registration id. This enables the number being used as id and the name for authentication.
  • Redirection with GK ID If enabled and the user registration is redirected, the GK ID of the redirecting PBX is appended to the registration to the redirected PBX.
  • Enbloc Dialing If enabled, the dialed numbers will be sent together within the setup message after timeout.
  • Allow DTMF through RTP If enabled, DTMF capability through RTP is allowed.
  • Enable messaging to PBX Message will be send via SIP or H.323, if disabled messages will be sent via the Polycom MSF-Module.
  • Idle Display Update Enables idle display updates.
  • Disable broadcast delay For small installations it is not necessary to delay the broadcasts for incoming calls to the radios. Enabling this option is not recommended for big systems.