Howto:Firmware Upgrade V7 V8: Difference between revisions
Jump to navigation
Jump to search
(New page: TBD) |
mNo edit summary |
||
Line 1: | Line 1: | ||
==Applies To== | |||
This information applies to | |||
* all V8 capable innovaphone devices | |||
<!-- version 8 --> | |||
==More Information== | |||
===Problem Details=== | |||
===Upgrade and Downgrade=== | |||
The upgrading and downgraing procedure for firmware is according to V7 as described in [[Howto:Firmware_Upgrade_V6_V7]]. | |||
=== Configuration Changes === | |||
====PBX Object==== | |||
The Object type for a physical PBX is changed from '''Node''' Object to '''PBX''' Object. | |||
===Known Problems=== | |||
==== H323 EFC encoding changed ==== | |||
*Starting with V8 H323 EFC encoding is changed as described in the bug note [[Support:DVL-Hotfixes#coding_of_H.323_EFC_wrong]]. It results in not ringing V6,V7 phones, if called by V8 PBX. | |||
Pre-V8 devices must be updated to recent V6 or V7 version, to be compatible to V8 or following configuration change must be done on the pre-V7 device, if no update to recent V6 or V7 is possible: | |||
config change H323 /fix 1 | |||
== Related Articles == | |||
*[[Howto:Firmware Upgrade V6 V7]] | |||
*[[Support:DVL-Hotfixes#coding of H.323 EFC wrong]] | |||
[[Category:Howto|{{PAGENAME}}]] | |||
<!-- Keywords: --> |
Revision as of 17:15, 1 July 2009
Applies To
This information applies to
- all V8 capable innovaphone devices
More Information
Problem Details
Upgrade and Downgrade
The upgrading and downgraing procedure for firmware is according to V7 as described in Howto:Firmware_Upgrade_V6_V7.
Configuration Changes
PBX Object
The Object type for a physical PBX is changed from Node Object to PBX Object.
Known Problems
H323 EFC encoding changed
- Starting with V8 H323 EFC encoding is changed as described in the bug note Support:DVL-Hotfixes#coding_of_H.323_EFC_wrong. It results in not ringing V6,V7 phones, if called by V8 PBX.
Pre-V8 devices must be updated to recent V6 or V7 version, to be compatible to V8 or following configuration change must be done on the pre-V7 device, if no update to recent V6 or V7 is possible:
config change H323 /fix 1