Sometimes it is desirable to set a device to factory defaults using the web interface.  Here is how.


===Resolution===
===Resolution===

Revision as of 14:51, 21 August 2014

Applies To

This information applies to

All innovaphone devices with Linux Application Platform installed.


More Information

Problem Details

Resolution

Use the following command sequence (using e.g. http://x.x.x.x/!cmd):

config clear
config write
vars del
mod cmd FLASHMAN0 reset data erase
ireset

Known Problems

  • The procedure might change with releases.
  • Factory settings do also apply to the IP/DHCP configuration. The device may thus be unreachable after.