Howto:SIP Interworking Interoperability HiPath 4000: Difference between revisions

From innovaphone wiki
Jump to navigation Jump to search
Line 261: Line 261:


=== innovaphone configuration ===
=== innovaphone configuration ===
[[image:Howto-SIP_Interworking_Interoperability_HiPath_4000_Sip_hiptah1.png]]


=== 3rd party product configuration ===
=== 3rd party product configuration ===

Revision as of 15:57, 15 March 2010

3rd party input
this is 3rd party content not provided by innovaphone, see history for authors.

SIP Interworking with Siemens HIPath 4000


Summary

SIP trunking between innovaphone PBX and Siemens HIPath 4000 PBX. It is recommended to use V5 on Siemens PBX, older Versions are not stable and also not fully SIP featured.

Version

  • Siemens HIpath 4000, Interface card HG 3500
  • Version 5.0
  • innovaphone Firmware: v8 HF1


Configuration

SIP trunking without registration

On the Siemens PBX SIP native must be configured, on innovaphone side configure a Gateway interface without registration , protocol SIP/UDP. For configuration details see below.

Test Results

Basic Call

Tested feature Result
call using g711a Yes
call using g711u Yes
call using g729 Yes
Overlapped sending Yes
Early media channel Not tested
Device shows called id number Yes
Device shows called id name One Way
Device shows called id display info One Way
Fax using T.38 Yes
CGPN can be supressed Yes
Reverse Media Negotiaton Not tested
Device shows CDPN/CGPN on incoming call Yes
Device shows CDPN/CGPN on outgoing call Yes
Device shows connected number No
Device shows diverting number No
Device supports distinctive ringing Yes
Device supports asymetric codec negotiation Yes
Device supports codec renegotiation during a conversation No *
Device shows correct display message in case of busy CDPN Yes
Device shows correct display message in case of not existing CDPN Yes
Device shows correct display message in case that the call is declined Yes
SOAP Call works? Not tested
Long Time Call (>30 min) works? Not tested
Voice Quality OK? Yes
  • it is recommended that you configure Media relay and a fixed codec on the innovaphone gateway, as the Siemens PBX does not support codec renegotiation.

DTMF

Tested feature Result
DTMF tones sent correctly Yes
DTMF tones received correctly Yes


Hold/Retrieve

Tested feature Result
Device handles incoming hold correctly Yes
Device can put a call on hold using correctly(inactive or sendonly) Yes

Transfer with consultation

Tested feature Voice Ok? MoH Ok?
inno1 calls inno2. inno2 transfers to testphone. Yes Yes
inno1 calls inno2. inno1 transfers to testphone. Yes Yes
inno1 calls testphone. inno1 transfers to inno2. Yes Yes
inno1 calls testphone. testphone transfers to inno2. Yes Yes
testphone calls inno1. inno1 transfers to inno2. Yes Yes
testphone calls inno1. testphone transfers to inno2. Yes Yes

Transfer with consultation (alerting only)

Tested feature Voice Ok? MoH Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes Yes
inno1 calls inno2. inno1 transfers to siemens. Yes Yes
inno1 calls siemens. inno1 transfers to inno2. Yes Yes
inno1 calls siemens. siemens transfers to inno2. Yes Yes
siemens calls inno1. inno1 transfers to inno2. Yes Yes
siemens calls inno1. siemens transfers to inno2. Yes Yes

Blind Transfer

Tested feature Voice Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes
inno1 calls inno2. inno1 transfers to siemens. Yes
inno1 calls siemens. inno1 transfers to inno2. Yes
inno1 calls siemens. siemens transfers to inno2. Yes
siemens calls inno1. inno1 transfers to inno2. Yes
siemens calls inno1. siemens transfers to inno2. Yes

Blind Transfer (alerting only)

Tested feature Voice Ok?
inno1 calls inno2. inno2 transfers to siemens. Yes
inno1 calls siemens. siemens transfers to inno2. Yes
siemens calls inno1. inno1 transfers to inno2. Yes

Broadcast Group & Waiting Queue

Tested feature Result
siemensmakes call to a Broadcast Group. inno1 picks up. Yes
inno1 makes call to a Broadcast Group. siemens picks up. No
siemens makes call to a Waiting Queue. inno1 picks up before announcement is played. Yes
siemens makes call to a Waiting Queue. inno1 picks up after announcement is played. Yes
inno1 makes call to a Waiting Queue. siemens picks up. No

Configuration

innovaphone configuration

3rd party product configuration

HIPath configuration

Known Problems

  • On Siemens side en-block dialing must be enabeld, as the Siemens can only send numbers via Sip in en-block dial.
  • CCBS/CCNR is not possible.
  • Calls from Siemens to innovaphone , the connected Name will not be shown up on the Siemens Endpoint.

Related Articles