Howto:Volume levels on an IP50 or IP52, IP54: Difference between revisions
(New page: Volume Levels for Mic and Speaker Gain can be set on the handsets too. ==Applies To== This information applies to * IP 50 * IP 52 * IP 54 ==More Information== The volume on the handset...) |
No edit summary |
||
Line 44: | Line 44: | ||
· Communication Tab | · Communication Tab | ||
. your COM Port | |||
. PP1-PP4 … for IP50 Handsets | |||
. PP5/40XX for IP52/54 Handsets | |||
Put the Handset into the cradle and hit “set comport” in the Communications Tab. A Message like “PP connected” should appear in the bottom line of the Servic Tool Window. | Put the Handset into the cradle and hit “set comport” in the Communications Tab. A Message like “PP connected” should appear in the bottom line of the Servic Tool Window. | ||
Now go to the Gain Control Tabs, “Gain Control” for IP50 and “Gain Control 40XX” for IP52/IP54 Handsets. First read the old values from the Handset by pressing on “Read gain value” and adjust the values to your needs. After that write them back to the Handset with pressing the “Write gain values”. | Now go to the Gain Control Tabs, “Gain Control” for IP50 and “Gain Control 40XX” for IP52/IP54 Handsets. First read the old values from the Handset by pressing on “Read gain value” and adjust the values to your needs. | ||
After that write them back to the Handset with pressing the “Write gain values”. | |||
Turn the Handset off and on to re-read the new settings | Turn the Handset off and on to re-read the new settings |
Revision as of 16:21, 4 May 2007
Volume Levels for Mic and Speaker Gain can be set on the handsets too.
Applies To
This information applies to
- IP 50
- IP 52
- IP 54
More Information
The volume on the handset is too low, although the speaker level is set to maximum via the volume keys.
System Requirements
Windows PC with serial interface
· Kirk Service Tool
. for download see related articel
· Programming cable
· IP50 programming cradle (DECT Charger with 3 Pins)
· IP52/54 programming cradle (DECT Charger with 3 Pins)
· Y-Connector
· Power Supply (for IP50 or IP52/54 DECT Charger)
Installation
Install the Kirk Service Tool following the instruction on the screen.
Connect the Y-Connector in the with on side to the docking station, on the other side connect the power supply and the programming cable to the connector.
Put the programming cable with the serial connector into the PC.
Plug in the Power Supply and insert a Handset to the cradle.
Configuration
In the Kirk Tool setup the following points:
· Communication Tab
. your COM Port
. PP1-PP4 … for IP50 Handsets
. PP5/40XX for IP52/54 Handsets
Put the Handset into the cradle and hit “set comport” in the Communications Tab. A Message like “PP connected” should appear in the bottom line of the Servic Tool Window.
Now go to the Gain Control Tabs, “Gain Control” for IP50 and “Gain Control 40XX” for IP52/IP54 Handsets. First read the old values from the Handset by pressing on “Read gain value” and adjust the values to your needs.
After that write them back to the Handset with pressing the “Write gain values”.
Turn the Handset off and on to re-read the new settings