Howto:Factory Reset using the Web Interface or Update Script: Difference between revisions

From innovaphone wiki
Jump to navigation Jump to search
Line 26: Line 26:


*This doesn't apply to innovaphone Softwarephone.
*This doesn't apply to innovaphone Softwarephone.
*The procedure removes also the important option /cipher in the DECT base station IP1202 which is needed. Call this command to fix it after the clear command:<br/> !config add DECT /cipher<br/> !config write


[[Category:Howto|{{PAGENAME}}]]
[[Category:Howto|{{PAGENAME}}]]

Revision as of 16:48, 25 September 2014

Applies To

This information applies to

All innovaphone devices, Version 7 and later


More Information

Problem Details

Sometimes it is desirable to set a device to factory defaults using the web interface. Here is how.

Resolution

Use the following command sequence (using e.g. http://x.x.x.x/!cmd):

config clear
config write
vars del
mod cmd FLASHMAN0 reset data erase
ireset

Known Problems

  • The procedure might change with releases.
  • Factory settings do also apply to the IP/DHCP configuration. The device may thus be unreachable after.
  • This doesn't apply to innovaphone Softwarephone.
  • The procedure removes also the important option /cipher in the DECT base station IP1202 which is needed. Call this command to fix it after the clear command:
    !config add DECT /cipher
    !config write