Summary
As a conclusion of the test with this products, innovaphone can only recommend to use the Tanndberg T150 as a SIP device. When using H.323 as signalling protocol, a call transfer is not possible. Since this is a serious limitation, innovaphone does not recommend using the Tandberg T150 as a H.323 device.
Version
T150 - Firmware Version:
L4.2, Security
T150 - Hardware Version:
38A02282
innovaphone IP800 - Firmware Version:
V7(08-70015)
Current test state
This product is being tested right now. The test is not yet completed.
Testing Enviroment
Scenario: Tandberg only phone equipment
Device Setup
Tested feature
|
Result
|
Register Device w/o specific configuration (requires DHCP, GK detection and “magic” alias)
|
No
|
DHCP is default
|
Yes
|
DHCP works
|
Yes
|
DHCP yields timeserver and time displays correctly
|
Yes
|
SNTP config has TZ string for timezone/dst autoconfig
|
No
|
DHCP yields correct default gateway
|
Yes
|
Device supports magic registration (e.g. by serial)
|
No
|
GK discovery works
|
Yes
|
Fixed GK registrations works
|
No
|
Registrations supports GK-ID
|
No
|
Device registers w/o Extension (just by name)
|
Yes
|
Device registers by extension
|
Yes
|
Device registers with H.235 password
|
Yes, but no calls possible
|
Device registers multiple identities
|
No
|
Test Results
Basic Call
Tested feature
|
Result
|
call using g711a
|
Yes, oneway
|
call using g711u
|
Yes, oneway
|
call using g723
|
No
|
call using g729
|
No
|
Overlapped sending
|
No
|
early media channel
|
No
|
Fax using T.38
|
N/A
|
CGPN can be supressed
|
No
|
Reverse Media Negotiaton
|
No
|
Voice Quality OK?
|
Yes
|
Calls from T150 to IP230 have one way audio from IP230 to T150 only. Calls from IP230 to T150 are OK.
DTMF
Tested feature
|
Result
|
DTMF tones sent correctly
|
Yes
|
DTMF tones received correctly
|
Yes
|
Device switches to DTMF mode automatically after connect
|
Yes
|
Hold/Retrieve
Tested feature
|
Result
|
Call can be put on hold
|
Yes, but sometimes without MoH
|
Held end hears music on hold / announcement from PBX
|
Yes
|
can put call on hold
|
No
|
can create secondary outgoing call
|
No
|
can accept a secondary incoming call
|
No
|
can terminate either call and retrieve remaining call
|
No
|
can toggle between both calls, media stream ok
|
No
|
call can be held remotely and retrieved remotely, media stream ok
|
Yes, but sometimes without MoH
|
signals call hold to GK
|
No
|
Transfer with consultation
Tested feature
|
Result
|
Device can be transferred by far end (check media ok, display on all 3 phones ok)
|
A calls T, A calls B, A xfers T to B
|
OK, T shows number from A after transfer
|
A calls B, B calls T, A xfers B to T
|
OK, T shows number from A after transfer
|
T calls A, B calls A, A xfers T to B
|
NOK, transferred call without media
|
B calls A, T calls A, A xfers B to T
|
OK, T shows number from A after transfer
|
Device can transfer both call ends (media ok, display on all 3 phones ok?).
|
T calls A, t calls B, t xfers A to B
|
N/A
|
T calls B, t calls A, t xfers B to A
|
N/A
|
A calls t, B calls t, t xfers A to B
|
N/A
|
B calls t, A calls t, t xfers B to A
|
N/A
|
Hints:
- A - first innovaphone Terminal
- B - second innovaphone Terminal
- T - tested 3rd party Terminal
Blind Transfer
Tested feature
|
Result
|
Device can be transferred by far end (check media ok, display on all 3 phones ok)
|
A calls T, A xfers T to B
|
No, no media after transfer
|
A calls B, A xfers B to T
|
No, transfer fails
|
T calls A, A xfers to B
|
No, transfer fails
|
Device can transfer blindly (media ok, display on all 3 phones ok?).
|
T calls A, T xfers to B
|
N/A
|
A calls T, T xfers to B
|
N/A
|
Call Forward
Tested feature
|
Result
|
Device displays current call forwarding (interrogation)
|
CFU
|
No
|
CFNR
|
No
|
CFB
|
No
|
Device can set call forwarding
|
No
|
T150 interpretes this signalling like a normal call, without any sound.
Other Features
Directory
Tested feature
|
Result
|
Device built-in directory
|
Exists
|
Yes
|
Can be dialled from
|
Yes
|
Does CLI resolution
|
Yes
|
Hands free
Tested feature
|
Result
|
Loudspeaker operation works fine
|
Yes
|
Hands free works fine
|
Yes
|
Volume adjustable during call
|
Yes
|
Keys
Tested feature
|
Result
|
Device has speed dial keys
|
6 Keys
|
Device has programmable function keys
|
No
|