Revision as of 18:16, 10 February 2014
Applies To
This information applies to
All innovaphone devices, Version 7 and later
More Information
Problem Details
Sometimes it is desirable to set a device to factory defaults using the web interface. Here is how.
Resolution
Use the following command sequence (using e.g. http://x.x.x.x/!cmd
):
config clear config write vars del mod cmd FLASHMAN0 reset data erase ireset
Known Problems
- The procedure might change with releases.
- Factory settings do also apply to the IP/DHCP configuration. The device may thus be unreachable after.
- This doesn't apply to innovaphone Softwarephone.