Howto:Alarm365 - ATT AG - 3rd Party Product
Product Name
ATT AG - Der Alarmserver. [1]
Certification Status
Category
Alarm system/server solutions
Vendor
Serinus has its roots in the Ruhr area and was founded with the aim of providing an alert, information and collaboration platform that is simple, fast and reliable at the same time. This is a solution that can be intuitively operated by decision-makers even under enormous pressure. To develop this solution, the three founders could fall back on their together over 40 years of experience in the fields of IT, telecommunications, security technology as well as alarm and crisis management. Serinus is already one of the world’s leading providers in the field of smart event communication, shortly after its foundation.
Description
Combine the benefits of the server and cloud-based solutions with Serinus Hybrid. This version provides you the versatility and low-maintenance operation typical of Serinus SaaS combined with the individual capabilities and interface connection of Serinus On-premises. Using the local alarm media gateway, you can link not only standard but also manufacturer-specific interfaces and transmit all the notifications directly to your existing communication infrastructure.
Benefits at a glance:
- Independence from the infrastructure: web-based alert and crisis management platform
- Failover protection: geo-redundant cluster operation
- Ease of integration: alarm media gateway with redundant network connection (LTE backup)
Available Languages
- German
- English
Functions
A lightning strike in the data centre, flooding in your region, an emergency case in the production line – whenever the worst case scenario occurs, it is important to be prepared. According to a defined set of rules, Serinus transmits alarms using all the available communication channels, while informing users about certain events and which responses are expected from them. Through the confirmation function, Serinus receives a qualified feedback on the availability and response times of your teams. All alerting operations are logged in detail and can be used for process improvement.
Key features in combination with Innovaphone:
- Display text on Deskphones and Dect-Phones
- Confirmation via DTMF ( positive, negative, PIN-based, Time)
- Textmessage via SOAP Interface
- Loudspeaker broadcast
- Control call forwarding
- Call intrusion
- Call recording
- LDAP Integration Innovaphone to import User
- Localisation
Offered Interfaces
- Digital contact inputs and outputs
- Serial connections via ESPA 4.4.4
- IP integration via ESPA-X, KNX, Modbus, BACnet
- Connection through OPC
- REST API Interface
- SMS
Use Cases
Alerting
- On-call service alerting
- MCI alerting
- Convening of crisis task forces
- First-aiders emergency call
- Fire and evacuation alert
- Silent alarm
Crisis management
Technical Monitoring
Version
Product versions used for interop testing:
- Serinus MG Version 1.1
- innovaphone V12 R2 SR17 IPVAC 12.5.3.717
Configuration
SIP configuration with Mediagateway Version 2.0.0.x
to be done by serinus
SIP configuration with Mediagateway Version 1.0.22.x
There are two ways how to connect the serinus Mediagateway to a innovaphone telephone system:
- The connection as an (SIP-) object will be easy and fast but does not have many configuration possibilitys. - connecting as an gateway trunk has much more possibilities like codec selection, routings,,...
In both ways calling the mediagateway through an range of numbers is possible (e.g. 99 000-999).
Which way to choose should be the decission of the technician that supports the telephone system.
SIP configuration
overview of both sip connectors in the Mediagateway (example)
this example shows the two ways how the mediagateway can be connected as described before.
Here we used the following configuration examples:
Serinus Mediagateway: 192.168.8.25
Innovaphone PBX: 192.168.8.171
TelNbr Mediagateway way1: 91-xxxx
TelNbr Mediagateway way2: 71-xxxx
Way1: register as gateway-object
These images shows the gateway object Serinus_Mediagateway1 No 91
Create a new gateway object
To create a new sip connector on the Serinus Mediagateway go to Menue - connectors - new SIP Connector
Add a connection name, the serveradress of the innovaphone pbx, the portnumber, the protocoll and the authentication details
After adding the connection details you can start a testcall to a telephonenumber through entereing the phonen number and pressing the button "call".
The "send message" button can be used with some pbx systems to send a SIP-textmessage (if supported by the pbx)
The extended sip logging can be activated already at the beginning to have a better overview through the logfiles if connection problems may occure. It must be deactivated afterwards to prevent the system to becoming slow.
"Take incoming call before reject or go further" can optionally be activated if the function "silent alerting" will be used. This can prevent the telephone from playing a short dialtone when the silet alert key is pressed.
The pbx-prefixes are not used in this version. These mask is only for documentation purposes.
To be able to make a external call, please add the external prefix to the external phone number within the persons.
Way2: Gateway trunk connection
These images shows the gateway object Serinus_Mediagateway71 No 71
Create a new gateway object
In this picture we have two different Mediagateways configured and connected
As soon as all configuration steps are made in the innovaphone pbx, the gateway object and the GW from the menue GK will connect to each other (you can see this here under "Alias")
On the innovaphone configuration page go to: Gateway - GK - GW1
Enter the details as shown above. Use Protocol TCP, Remote Domain is this own PBX (!). Under "Alias List", enter the name and the number of the above created gateway object. Select the codec G722. Use no encryption.
If more than one pbx system or Mediagateways are connected, you can add a route to allow calls between them.
To create a new sip connector on the Serinus Mediagateway go to Menue - connectors - new SIP Connector
Add a connection name, the serveradress of the innovaphone pbx, the portnumber, the protocoll and the authentication details
After adding the connection details you can start a testcall to a telephonenumber through entereing the phonen number and pressing the button "call".
The "send message" button can be used with some pbx systems to send a SIP-textmessage (if supported by the pbx)
The extended sip logging can be activated already at the beginning to have a better overview through the logfiles if connection problems may occure. It must be deactivated afterwards to prevent the system to becoming slow.
"Take incoming call before reject or go further" can optionally be activated if the function "silent alerting" will be used. This can prevent the telephone from playing a short dialtone when the silet alert key is pressed.
The pbx-prefixes are not used in this version. These mask is only for documentation purposes.
To be able to make a external call, please add the external prefix to the external phone number within the persons.
SOAP connection
The SOAP connection is used for forced release or loudspeaker announcements
Create a new user in the innovaphone pbx
It should have the rights to control all affected system phones
Once done, go back to the mediagateway SIP connector and add the credentials
When all settings are correct, the test button will show up a positive confirmation.
If it always fails, please try a password with less than 16 signs.
Settings for automatic call answer on system phones
Settings for forced release on nearly all phones (system phones, sip phones and also system dect phones)
Summary
Test Report Serinus
Media:Zertifikat_Serinus_und_innovaphone_19032019.pdf
Media:Zertifikat_Serinus_und_innovaphone_19032019_EN.pdf
Remark innovaphone AG:
- above listed "certificates" and test reports have been created by manufacturer itself and not by innovaphone itself.
- innovaphone has not conducted any tests nor can confirm functionality as indicated by manufacturer.
Contact
Serinus GmbH |
Benjamin Lieber |
Albrechtstraße 52 |
58089 Hagen |
Tel: +49 2331 97642 20 |
Mobile: +49 176 610 93 462 |
Mail: benjamin.lieber@serinus-sec.de |